RadioFrame System 
Operations and Maintenance 
RFN_3.1 Beta
  
135 
Alarm 
Description 
Action 
NET POOL ERROR 
The free Mblock cluster has gone below 40 
on an NPC or AP, the threshold for 
APC_NETPOOL_LOWMARK or 
NPC_NETPOOL_LOWMARK. 
Causes a system reset. 
 
OVERTEMP 
A chassis has overheated. 
Check the chassis for 
proper operation. 
PEER LOSS 
Communication with a board has been lost.  
RIC has detected a PEER LOSS from the 
RLIC. 
Causes a system reset, unless the cause is 
a DHRB, which self resets.  
 
PLL LOCK 
A RIC or RLIC PLL went out of lock. 
The RLIC locks and de-key all BRs, and 
then sends a state change trap to the iSC. 
 
RB ALARMS-CRC 
An RB has generated a RIC CRC error 
within the last 30 minutes. 
Monitor the RB/RFU 
and if it keeps 
incrementing, replace 
the RB/RFU. 
RB ALARMS-MISC 
An RB has generated a RIC error other than 
the CRC error.  
If this alarm occurs 
frequently while the 
system is running, 
monitor the RIC.  
RB CALIBRATION 
The RB did not reset after three attempts 
due to a Bad VGA. 
Identify the RB and 
replace it. 
RB E2 READ ERR 
RBSession EEPROM read attempts have 
failed beyond threshold. 
The RB goes into an error state. 
Replace something. 
RB ERROR STATE 
The RB has gone into an error state 
because there was either an error reading 
I/Q DAC values, or the values were invalid. 
Identify and replace the 
RB. 
RB SLOT MISS 
APC has detected an RB in the wrong slot.  
APC sends a message to the RIC with the 
RBIndex. 
Causes slot synchronization for the RB. 
 
RB SYNC FAIL 
Three consecutive attempts to sync up the 
RB failed. 
Reset the SPAM. 
RB TX GAIN CAL 
 
 
ROM MISMATCH 
Board boot version is not the same as the 
RLIC. 
 
SPAM FAILED 
Lost DSP PDUs have exceeded threshold. 
SPAM is reset. 
 
SW VER MISMATCH 
Board software version is not the same as 
the RLIC. 
 
SYSTEM RESET 
Alarms that result in a system reset cause 
thi
l
t f
th RLIC