Method of Procedure 
Pre-Installation 
46 
RFN_3.1 Beta
 
3.6.5 Grounding 
• 
No additional grounding is required 
3.6.6 Environment 
• 
Operating Ambient Temperature: 0
o
C to +40
o
C (+32
o
F to +104
o
F) 
• 
Altitude: -200 to +8000 feet above mean sea level; above 8000', reduce 
maximum operating ambient temperature by 2
o
C per 1000' to a maximum of 
13000' 
• 
Storage Temperature: -40
o
C to +70
o
C (-40
o
F to +158
o
F) 
• 
Relative Humidity: 10-90% non condensing 
• 
Shock: 40 g’s 
• 
Vibration:  Level 3 earthquake 
• 
Keep product free from dust, wind, salt, liquids 
3.6.7 Heat 
Load 
• 
Not applicable 
3.7 RAPs 
3.7.1 Mounting 
• 
The 802.11b RadioFrame Access Points (RAPs) are inserted into the RFU. 
• 
RFUs must be mounted in such a way that the RAP antenna points 
downward to the ground.  
3.7.2 Clearances 
• 
Dimensions: 3” wide x 4” high (plus antenna) x 0.5” thick (approx.) 
• 
The RAP is housed in the RFU. If the RAP is properly inserted into the RFU, 
no additional clearances are required. 
3.7.2.1 Back 
• 
0”