USER MANUAL FOR COMFLEX-6900  
 
ENU STATUS : 1-0-0 
Copyright - refer to title page 
Page 37 
 
 
 
 
 
4  COMMISSIONING 
4.1  PRE-COMMISSIONING TASKS 
After equipment installation, perform the following steps before equipment powering and commissioning, 
check  that  the  expected voltage,  current,  and  power  levels  do  not  violate  any  ratings.  Double  check  all 
connections including ground before applying power.  Do not manipulate circuits or make changes  when 
power is applied: 
 
  Visually inspect the power connection within the equipment. Ensure that all cables are correctly and 
securely connected, including power cables, grounding wires, RF cables and optical cables.  
  Check grounding connection and verify that the ground resistanc
e is less than 5Ω. 
  Connect the equipment to the PC.  
  Power on MU and RU. 
  Monitor  the initialization  of  the  MU  and  RU  though the  LEDs  on the  panel.  Refer  to  detailed  LEDs 
information in the next section. 
 
 
4.2   LED INDICATORS 
Diagnostic LEDs are located on the MU front panel and RU bottorm panel; each indicates the status of a 
particular function: 
 
Table 7: MU LED Indications 
LED Indicator 
Normal Status 
Indication 
PWR 
Steady green 
Power indicator. If LED is off, it indicates the system has 
no power.  
RUN 
Flashing green 
(1 time/sec) 
MU operation indicator. After initialization (1~2 minutes), 
the LED should flash at once per sec. (When upgrade 
firmware, LED will flash rapidly)  
ALM 
OFF 
Alarm indicator. If LED is RED, there is an alarm. 
OP 
Steady green 
Located on Fiber Optical Unit (FOU), it is an indicator for 
receive optical power. If LED is off, it indicates the 
receiving optical power is less than -10dBm. 
 
Table 8: RU LED Indications 
LED Indicator 
Normal Status 
Indication 
COMM. 
Blinking green 
(1 time/sec) 
BLINKING GREEN - Flashes (rate of flash per second) 
for the duration of 1 minute upon communication 
initialization 
RAPID/NO FLASH - Indicates communication fault 
RUN 
 Off 
OFF 
– Normal operation 
RED - Fault 
ALM 
Off 
Alarm indicator. If LED is RED, there is an alarm. 
LED Indicator 
Normal Status 
Indication