6  ALARMS AND TROUBLESHOOTING 
6.1  ALARMS 
Table 12: MU Alarm List 
Alarm List 
Alarm Condition 
Over-Temperature 
Alarm 
 
Alarm when equipment temperature is higher than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold : 80
℃ by default. 
Optical Tx Alarm 
 
Alarm when Optical Transmiting power is lower than the threshold, 
otherwise normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold: -7dBm by default. 
Optical Rx Alarm 
 
Alarm when Optical received power is lower than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold: -10dBm by default. 
DL Input Power 
Overload Alarm 
 
Alarm when DL input power is higher than the threshold, otherwise normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold: 32dBm by default.