8. Description of circuit employed for suppression of spurious 
radiation
 
 
In the CDMA transmit signal path, the frequency spectrum at the output of the CDMA DACs contains 
unwanted frequency components due to the DAC output transition edges and transients. The 
transmit clock frequency and harmonics are found in the spectrum. 
Each CDMA DAC is followed by an anti-aliasing low-pass filter with a bandwidth of 630 KHz that 
reduces unwanted frequency components installed in MSM5500. And then Tx IF frequency from the 
RFT3100 is filtered by band-pass filter. The nominal specification of the filter is as following.
 
Nominal center frequency : 138.6 MHz 
3 dB Bandwidth                      : ± 630 kHz 
Stop band attenuation    :  40dB min. 
The Tx RF output of the Tx Mixer and the AGC amp is filtered again by the SAW band pass filter. 
The nominal specification of the filter is as follows. 
Pass band    : 824 MHz ~ 869 MHz 
Attenuation    :    DC ~ 800MHz                : 22 dB min. 
                                      869 MHz ~ 1049 MHz : 25 dB min. 
                         
              1049 MHz ~ 2000 MHz : 19 dB min. 
Finally, the spurious generated from Power AMP is filtered by the duplexer. The nominal specification 
of the duplexer is as follows 
TX Pass band        : 824 MHz ~ 869 MHz 
Attenuation    : 869 MHz ~ 894 MHz : 40 dB min.