Opticon Sensors Europe BV H22-RFID 사용자 설명서

다운로드
페이지 108
Opticon 
H-22 User Manual 
 
 
 
105 
then automatically set the device in flight mode and disable all functionality but the absolute 
necessary to keep the current state of the device. The user may remove the battery to replace it with 
another battery as soon as the display has been turned off. During the battery change the system 
power is supplied from a Li-ion cell dedicated for the hot swap functionality. The system state can be 
sustained without main battery for up to 3 minutes without data loss. When a new battery is inserted 
and the battery lid is closed the device can be woken by pressing the power key. The device will be 
in the same state as when the battery lid was removed. H22 measures the charge status of the 
backup battery and ports it through the battery control panel applet. The charging status is either 
“Good” or “Not Good”. In case the backup battery status is indicated as “Not Good” a Hot swap must 
not be performed since it might result in loss of user data. The backup battery is automatically 
charged from the main battery as soon as the main battery is present in H22. 
 
To check backup battery status: 
1. 
Tap        > Settings > System > Power
2. 
Select the Battery tab. 
3. 
If the backup battery status is “Good” a hot swap is possible 
 
 
 
NOTE: Any ongoing activity such as data transfer or voice call will be broken during hot swap. Data 
transfers and similar activities have to be restarted after a hot swap. 
 
NOTE: Before performing a hot swap, check that the backup battery status is OK in battery control 
panel.