Radwin Ltd. WINLINK 사용자 설명서

다운로드
페이지 65
Quick Start Guide 
AirMux-104 Installation and Operation Manual 
Installing AirMux-104 Units 
 
 
To align the RTs: 
1.  Connect power to the RTCBs. 
2.  Turn the local RT in the direction of the remote RT. 
3.  At the remote site, align the RT to face the local RT. (Align visually or by using 
a map and a compass). Use the RSS/SNR, LINK and STATUS LEDs at the base 
of the RT for the link quality indication: 
 
RTs are not aligned: 
 
Triple RSS/SNR LED is blinking 
 
LINK LED is OFF 
 
STATUS LED is blinking slowly. 
 
RTs are aligned: 
 
Triple RSS/SNR LED is blinking or lit steadily  
 
LINK LEDs is lit steadily 
 
STATUS LED is blinking rapidly. 
4.  Repeat steps 3 to 4 for the local RT to complete the installation procedure. 
5.  Make sure that the management station is properly connected to the local 
RTCB, and the AirMux Manager application is running. 
6.  In the Main menu, click Monitor
7.  Verify the radio signal strength (RSS) and sound-to-noise ratio (SNR) in the 
Main menu.  
 
RSS is better than -88 dBm 
 
SNR must be at least 9 dB. 
 
Try achieving the best possible RSS and SNR values. 
 
8.  View these parameters for about 15 min. to verify stability. After achieving the 
best RSS and SNR levels, permanently attach the remote RTs to the mast/wall. 
 
Do not stand in front of live radio terminal. 
 
 
Performing Indoor Installation 
 
To connect user equipment to the RTCB: 
1.  Connect user mux or PBX to the RTCB rear panel RJ-45 port designated E1. 
2.  Connect user hub/router or any other compatible device to the RTCB rear 
panel RJ-45 port designated 10/100 LAN. 
Warning 
Note