Installing AirMux-104 Units
To align the RTs:
1. Connect power to the RTCBs.
2. Turn the local RT in the direction of the remote RT.
3. At the remote site, align the RT to face the local RT. (Align visually or by using
1. Connect power to the RTCBs.
2. Turn the local RT in the direction of the remote RT.
3. At the remote site, align the RT to face the local RT. (Align visually or by using
a map and a compass). Use the RSS/SNR, LINK and STATUS LEDs at the base
of the RT for the link quality indication:
of the RT for the link quality indication:
RTs are not aligned:
Triple RSS/SNR LED is blinking
LINK LED is OFF
STATUS LED is blinking slowly.
RTs are aligned:
Triple RSS/SNR LED is blinking or lit steadily
LINK LEDs is lit steadily
STATUS LED is blinking rapidly.
4. Repeat steps 3 to 4 for the local RT to complete the installation procedure.
5. Make sure that the management station is properly connected to the local
5. Make sure that the management station is properly connected to the local
RTCB, and the AirMux Manager application is running.
6. In the Main menu, click Monitor.
7. Verify the radio signal strength (RSS) and sound-to-noise ratio (SNR) in the
7. Verify the radio signal strength (RSS) and sound-to-noise ratio (SNR) in the
Main menu.
RSS is better than -88 dBm
SNR must be at least 9 dB.
Try achieving the best possible RSS and SNR values.
8. View these parameters for about 15 min. to verify stability. After achieving the
best RSS and SNR levels, permanently attach the remote RTs to the mast/wall.
Do not stand in front of live radio terminal.
Performing Indoor Installation
To connect user equipment to the RTCB:
1. Connect user mux or PBX to the RTCB rear panel RJ-45 port designated E1.
2. Connect user hub/router or any other compatible device to the RTCB rear
1. Connect user mux or PBX to the RTCB rear panel RJ-45 port designated E1.
2. Connect user hub/router or any other compatible device to the RTCB rear
panel RJ-45 port designated 10/100 LAN.