The Watt Stopper Inc. DRD40 사용자 설명서
CLEANING
Clean using a cloth dampened only with water and a little mild detergent.
Use of solvents or hydrocarbon-based cleaners may cause permanent damage.
TROUBLESHOOTING
During Set House ID, the LED is not flashing on some wireless Miro
devices.
devices.
• If LED is solid green before initiating House ID binding:
The device already has another House ID. Reset it to the factory
default so that it can be bound to the desired House ID. Resetting to
factory defaults is described in the “I need to start over” issue.
default so that it can be bound to the desired House ID. Resetting to
factory defaults is described in the “I need to start over” issue.
• If LED is solid yellow after initiating House ID binding:
The device may be out of range of the initiating device. Add a
MRR2G Miro Wireless Repeater to boost signal range.
MRR2G Miro Wireless Repeater to boost signal range.
I made a configuration mistake. I need to start over.
You can reset any Miro wireless device to factory default settings
by pressing and holding
by pressing and holding
until the LED changes to solid yellow
(approximately 10 seconds). During the process, the LED flashes yellow
and when complete, it changes to solid yellow. The device can then be
reconfigured, exactly like any new device (see the Set House
ID section).
and when complete, it changes to solid yellow. The device can then be
reconfigured, exactly like any new device (see the Set House
ID section).
The Dimmer does not work and the status LED is flashing red
•
at 1Hz (5 times in 5 seconds):
The dimmer has detected an unsuitable load or a load below 25 watts.
To clear the fault condition, tap
The dimmer has detected an unsuitable load or a load below 25 watts.
To clear the fault condition, tap
and wait for the LED to turn green.
Disconnect power, check the load, restore power and try again.
• at 2Hz (10 times in 5 seconds):
The dimmer has detected an overload condition and has shut down.
To clear the fault condition, tap
To clear the fault condition, tap
and wait for the LED to turn green.
Disconnect loads in excess of rated load and try again.
• at 3Hz (15 times in 5 seconds):
The dimmer has detected a short-circuit condition and has shut down.
To clear the fault condition, tap
To clear the fault condition, tap
and wait for the LED to turn green.
Remove power, rectify the short-circuit condition, restore power, and
try again.
try again.