ViVOpay 8850 User Guide
 14               
Troubleshooting and Maintenance
Onboard Diagnostics
Onboard diagnostics (OBD) tests the following components of the ViVOpay 8850.
Is there a smart card test? 
Accessing the OBD Tests
To enter the onboard diagnostics
1.
Power off the ViVOpay 8850 by removing the power supply from the power receptacle.
2.
Plug the power supply back into the power receptacle.
Communication to POS/ECR
No data is received, or data is 
garbled.
• Faulty or incorrect cable connections.
• Unsupported card used.
• Contactless application is not 
installed on terminal (for serial 
connections only).
• Magstripe card not swiped correctly. 
• Magstripe card not level during card 
swipe.
• The POS application is not using the 
correct communications parameters.
• Check that the cable connection is secure and 
in the correct port on the POS/ECR.
• Check that the POS/ECR has the correct 
software application to accept data from the 
contactless reader (may need assistance from 
the POS vendor).
• Try a different card/fob/phone or magstripe 
card if testing the magstripe reader.
• If testing with the magstripe card, try turning 
the card around; make sure that the card is 
level during the card swipe.
• Contact the payment processor for an 
application upgrade.
• Check that the cable is correctly attached to 
the back of the ViVOpay 8850
• Check the POS application.
Test
Possible Results
LCD Test
Pass/Fail
Touch Screen Test
Pass/Fail
Key Test
Pass/Fail 1234567890<cancel><backspace><enter>
LED Test
Pass/Fail
Buzzer Test
Pass/Fail
Magstripe Test
Pass Tracks 1 or 2 or 3/Fail
RFID Test
Pass Type A or B/Fail
Security Keys Test
KPK, DUKPT, Master 1234567890
Symptom
Possible Cause
Probable Cause and Remedy