Beijing Landwell Electron Technology Co. LTD LW19990824 사용자 설명서

다운로드
페이지 3
checkpoint tag stands for a patrol point, which is placed 
at  the  patrol  site  or  equipment.  Through  software  the 
information  tag  can  be  setup  as  different  checkpoint 
name which it relates to.   
1.3)b 
personnel  tag:  this  is  the  patrol  man‘s  ID  tag. 
Some tasks are carried out according to group of patrol 
man. Every group shares one reader. Every patrol man 
carries  his  own  personnel  tag  so  a  reasonable  patrol 
performance check is attainable.   
1.4) 
Software  management  system  ────  it  analyzes 
the  related  data  uploaded  and  after  data  processing,  it 
offers detailed patrol report. The software will match the 
patrol report  with plan, and correctly process the patrol 
result data.   
 
2. Hardware Directions 
2.1)    Patrol  reader:  when  patrol  man  reaches  the 
planned  site,  he  presents  the  reader  head  to  the 
checkpoint  tag  within  5cm  distance  (the  tag  frequency 
decides  the  distance).When  the  reader  sends  out 
"beep" sound  and the LED lights  3 times(the same tag 
cannot  be  reread  continuously  with  the  same  reader. 
One minute is the minimum interval before reread. The 
LED  will  light  once  when  reread  without  proper  time 
interval  ),it  means  the  data  is  collected  to  the  reader 
successfully.   
2.2)    Communication  line:  connect communication  line 
USB  head  to  the  computer  USB  port,  the  other  side  to 
the reader corresponding port.   
2.3)    Information  tag:  first  stir  super  glue(like  AB  glue) 
evenly  at  the  rate  of  1:1,spread  it  on  the  back  of  the 
patrol tag. Paste the patrol tag to the patrol point(like the 
surface of cement ,hard brick wall or other strong object. 
Choose flat surface before pasting the tag. If the surface 
is coarse, use sand paper to polish it.) 
 
3. Software Setup and Usage 
Please  read  the  software  manual  carefully  before 
software  installation.  Familiarize  with  the  software  step 
by step. The software 
administer’s access is Admin, the 
default pin is 333.   
3.1)  Information  tag  setup:  operate  according  to 
software  requirement  and  the  client  demands  :patrol 
record  upload 
——first clear the old data  in the reader 
through communication line.(by transmitting the data to 
computer  after  connecting  reader  with  computer  ,the 
reader's  stored  data  is  cleared.  The  data  can  be 
retransmitted  to  software  if  the  reader  does  not  read 
new  tag.  If  new  tag  is  read,  the  new  data  will  cover  all 
the  old  data  and  it  becomes  the  first  new  data 
record).Then  use  this  reader  to read  all  the  checkpoint 
tags  in  order.  Now  upload  these  data  to  the  related 
checkpoint setup or personnel setup.   
Specific operation method is as follows   
a  Plan  setup:  According  to  the  client's  situation,  setup 
the  patrol  route  points,  where  the  patrol  tags  will  be 
fixed.   
b Tag reading: after checkpoint    tag is installed, use the 
reader  without  data  to  read  all  the  tags  once,  then 
upload the  data to the checkpoint setup from software. 
Edit  the  checkpoint  name  following  the  reading  order. 
Another  way  is  before  checkpoint  tag  installation,  use 
reader  to  collect  all  the  tags’  ID  number.  It  is  better  to 
write  down  the  ID  number  by  its  last  5  to  6  digits 
together  with  the  point  name  it  stands  for.    This  is  to 
link  the  tag  ID  number  in  the  software  with  the 
checkpoint tag.   
 
System Installation and Usage Considerations 
 
1)    Let the reader's LED face you. Hold the reader like 
a pen with hand and arm at a 90 degree angle.   
2)    Place  the  patrol  reader  with  the  checkpoint  tag 
surface  at  a  45  degree  angle.  When  the  reader's  LED 
lights 3 times and the beeper sounds, data collection is 
done.  (If  it  is  noisy  on  site,  you  can  reread  the  tag  to 
make  sure  data  is  collected.  If  the  LED  lights  once,  it 
shows the first time reading is successful.) 
3)    Please  transmit  correct  tag  ID  number  for 
checkpoint and personnel setup, and input correct name 
for  each  checkpoint  and  personnel.  Each  tag  number 
and  related  checkpoint  or  personnel  is  unique.  One 
information  tag  can  only  be  setup  as  a  checkpoint  or 
personnel tag, it cannot be both at the same time.   
4)    If  the  data  collected  are  less  than  10,000  pieces 
after  patrol,  all  the  data  can  be  uploaded  through  the 
communication  line.  The  data  will  automatically  be 
cleared  during  transmittance.  The  reader  can  transmit 
the data again if it does not read new data. This function 
avoids data loss if problem occurs.   
5)    Do  not  read  data  more  than  the  reader's  capacity