BDA OVERVIEW: 
 
The BDA assembly extends the coverage area of radio communications in buildings 
and RF shielded environments. 
The unit features low noise figure and wide dynamic range. It is based on a duplexed 
path configuration with sharp out of band attenuation allowing improved isolation 
between the receiving and transmitting paths. 
 
BDA BLOCK DIAGRAM DESCRIPTION: 
 
Refer to figure 1 for the following discussion. 
 
The BDA Downlink path receives RF signals from the base station and amplifies and 
transmits them to the subscriber. The BDA Uplink path receives RF signals from the 
subscriber and amplifies and transmits them to the base station. The Uplink and 
Downlink occupy two distinct frequency bands. For example, the SMR frequency 
bands are as follows: 806-821 MHz for the Uplink and 851-866 MHz for the Downlink. 
Two diplexers isolate the paths and route each signal to the proper amplifying 
channel. 
 
A selectable Automatic Level Control (ALC) allows for output power limiting. A 
Manual Gain Control (MGC) provides continuous control of amplifier gain. The use of 
these controls is covered in the “OPERATION” section, later in this document.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page 3