1.  Important Safety Information 
The safety guidelines for InfoProx Entry include: 
·  Power sources 
·  ANSI/UL listing (USA) and CSA 22.2 listing (Canada) 
·  UL 294-compliant installations 
·  FCC Class A digital device 
·  Canadian Radio Emissions Requirements 
Power Sources 
To power the door latch, you should use a power limited UL 294 or UL 603 door 
strike power supply. You can obtain the door strike power supply from AlarmSAF, 
Altronix, Securitron, and Software House. You can also use the door strike power 
supply to provide power to the reader units. The typical load on the power supply is 
250 milliamps per reader. You can also power the readers by using the DIU 
supplied by Software House, or a Desktop Power Supply rated 12 VDC, 1.2 Amp 
minimum, with Class 2 and UL Markings. If you do not have a battery backup for 
the power supply, you cannot connect the power supply to a receptacle that is 
controlled by a switch. 
ANSI/UL listing (USA) and CSA 22.2 listing (Canada) 
A National Recognized Test Laboratory (NRTL) has examined and tested InfoProx 
Entry, EtherProx Entry, and InfoProx Exit readers according to the requirements of 
ANSI/UL 294 - Access Control System Units and CSA 22.2 No. 205-M1983. The 
readers are low-voltage 12-volt assemblies that operate from power limited 
sources. When you install a reader according to the instructions in this manual and 
wire it according to the National Electrical Code (NEC), you can expect the reader 
to meet all safety requirements. 
UL 294-compliant Installation 
To ensure a secure installation that is in full compliance with UL 294 requirements 
for security and performance, follow these guidelines: 
·  You must install the wiring for the door controls on the secured side of 
the premises. 
·  If you provide backup power with the installation, the batteries in the 12-
volt UL 294 or UL 603 power supply should provide power for the door 
strike and the readers for a minimum of four hours. If you do not 
provide backup power with the installation, make a permanent marking 
on the power supply label of the expected duration of the fully charged 
battery. The Software House DIU also provides battery power. 
Software House