Agrident Corporation AWR100 사용자 설명서

다운로드
페이지 31
08/10/2007 
Vertraulich / Confidential 
Page 19 of 31 
 
 
 
AWR100
 
 
 
Otherwise the last read transponders are displayed in the same format described in chapter 
4.2.1: 
 
 
     
 
 
 
 
4.4 Permanent 
Read 
If lots of transponders have to be read in a short distance or time, the Stick reader offers the 
permanent read mode. In this mode the reading of transponders goes on for a certain time in-
dependent of the successful reading of transponders. This mode is configurable by using the 
configuration software. 
 
4.5  Switch off time 
The Stick Reader is switched off automatically a certain time after last action (e.g. transponder 
read or menu access). The switch off time is configurable between 5 and 600 seconds by using 
the configuration software. 
 
4.6 Battery 
management 
If the battery is running low, a warning symbol (battery) appears after reading, right from the 
string. 
 
 
      
 
 
 
This symbol is telling the user, that it is time to replace or recharge the battery soon. 
 
If the Stick Reader detects a low battery directly after power on, the following information  
appears on the LCD display directly after power on: 
 
      
 
 
 
After displaying the information the Stick Reader is switched off automatically. 
 
The Stick Reader offers internal trickle charging for chargeable batteries. That means a com-
plete charging cycle takes min. 16 hours up to 20 hours (longer charging time is allowed). If the 
battery is charged completely, the charging will be stopped automatically. 
 
For faster charging cycles an external battery charger is available. 
For normal operation and internal trickle charge only the delivered 12V power supply has to be 
used. 
If the voltage of the used power supply is too high, the following information appears on the 
LCD display directly after start: 
 
 
 
      
 
 
 
After displaying the information the Stick Reader is switched off automatically. 
984 010900316360  
    12:41:26   F 
Press key    
 
     
Low battery   
     
    Warning  
  High voltage!