Operating Characteristics 
3.1 
Operating Modes 
The table below briefly summarizes the various operating modes referred to throughout the 
document.  
Table 4:  Overview of operating modes
 
Mode
 
Function
 
Normal 
operation
 
GSM / 
 
GPRS / UMTS / 
 
HSPA SLEEP
 
Power saving set automatically when no call is in progress and the USB 
connection  is  suspended  by  host  or  not  present  and  no  active 
communication via ASC0. 
 
GSM / 
 
GPRS / UMTS / 
 
HSPA IDLE
 
Power saving disabled or an USB connection not suspended, but no 
call in progress.
 
GSM TALK/ 
GSM DATA
 
Connection between two subscribers is in progress. Power 
consumption depends on the GSM network coverage and several 
connection settings (e.g. DTX off/on, FR/EFR/HR, hopping sequences 
and antenna connection). The following applies when power is to be 
measured in TALK_GSM mode: DTX off, FR and no frequency 
hopping.
 
GPRS DATA
GPRS  data  transfer  in  progress.  Power  consumption  depends  on 
network settings (e.g. power control level), uplink / downlink data rates 
and GPRS configuration (e.g. used multislot settings).
 
EGPRS DATA
 
EGPRS  data  transfer  in  progress.  Power  consumption  depends  on 
network settings (e.g. power control level), uplink / downlink data rates 
and EGPRS configuration (e.g. used multislot settings).
 
UMTS TALK/ 
UMTS DATA
 
UMTS data transfer in progress. Power consumption depends on 
network settings (e.g. TPC Pattern) and data transfer rate.
 
HSPA DATA
HSPA data transfer in progress. Power consumption depends on 
network settings (e.g. TPC Pattern) and data transfer rate.
 
Power 
 
Down
 
Normal shutdown after sending the power down command. Only a voltage regulator is 
active for powering the RTC. Software is not active. Interfaces are not accessible. 
Operating voltage remains applied.
 
Airplane 
 
mode
 
Airplane mode shuts down the radio part of the module, causes the module to log off from 
the GSM/GPRS network and disables all AT commands whose execution requires a radio 
connection.
 
Airplane mode can be controlled by AT command (see 
[1]
).
 
3.2  Power  Supply 
24
 
3.2 
Power Supply 
EHS6-A needs to be connected to a power supply at the SMT application interface - 2 lines 
BATT+, and GND. There are two separate voltage domains for BATT+: 
•  BATT+
BB
 with a line for the general power management. 
•  BATT+
RF
 with a line for the GSM power amplifier supply.