XT55/56 Hardware Interface Description 
Confidential / Preliminary 
s
 
XT55/56_hd_v02.96 
Page 66 of 125 
18.08.2005 
3.12 Control 
Signals 
3.12.1 Inputs 
 
Table 17: Input control signals of the GSM part of the XT55/56 module 
Signal  
Pin 
Pin status 
Function 
Remarks 
Falling edge 
Power up XT55/56
Ignition 
GSM_IGT 
 
Left open or HiZ  No operation 
Active low 
≥ 100ms (Open 
drain/collector driver to GND 
required in cellular device 
application). 
Note: If a charger and a 
battery is connected to the 
customer application the 
GSM_IGT signal must be 1s 
minimum. 
 
Low 
Power down 
XT55/56 
Emergency 
shutdown 
GSM_EMERG-
OFF 
Left open or HiZ  No operation 
Active low 
≥ 3.2s (Open 
drain/collector driver 
required in cellular device 
application). At the 
GSM_EMERGOFF signal 
the watchdog signal of the 
GSM engine can be traced 
(see description in Table 
27). 
 
 
(HiZ = high impedance)