IMPORTANT 
Prior to connecting any plug, make sure there is no water inside connectors. 
 
 
 
Electrostatic discharge: 
Use the following guidelines to provide a static-free repair station that will preclude any ESD-related 
damage to electronic circuits: 
• All spare parts (circuit boards and ESD sensitive devices) should be stored and transported in static- 
shielding bags. 
• Unless the repair station rests on a conductive floor, chairs or stools should rest on a grounded, rigid-
type, static-dissipative floor mat. 
• Use a static-dissipative table mat. 
• Wear a static-control wrist strap or foot grounder. 
• Provide common-point grounding for all conductive items (including personnel and soldering iron tip). 
• To control the discharge rate and protect workers from electric shocks, both the table mat and wrist 
strap should be grounded through a 1-MΩ resistor. The mat should be connected to the same earth 
ground point as the wrist strap. 
• Wear static-dissipative garments.