2.4.1.5 Standpipes and Stillwells
The R82 can be mounted in a standpipe or stillwell but
certain considerations should be given:
• Metal stillwells only: 2" (Sched 40 max.) to 4" (50–100 mm).
• Diameter must be consistent throughout length; no reducers.
• Stillwell length must cover complete range of measurement
(i.e., liquid must be in stillwell).
• Welds should be smooth.
• Vents: holes <0.125" diameter, slots <0.125" width.
• If an isolation valve is used, it must be a full port ball valve
with an I.D. equal to the pipe diameter.
• Bridles/Bypass Installations: The launcher should be rotated
90° from process connections.
• Configuration must include an entry for PIPE I.D.
See Section 2.6.5.1, Item 34- PIPE I.D.
• There will be some increased dielectric sensitivity; system
GAIN will be reduced when PIPE ID >0.
2.4.2 Installing the Transmitter
Install the Transmitter with its integral antenna by threading
into the vessel. DO NOT OVERTIGHTHEN as this may
cause damage to the plastic threads.
• Do not place insulating material around any part of the
radar transmitter including the antenna flange.
• Installation for NEMA 6P/IP 68- the transmitter can be
installed to allow for temporary submergence to 6 feet (1.8m):
- use TFE paste to seal conduit entries and antenna process
connection
- Do not overtighten housing cover; O-ring develops
water-tight seal without excessive tightening
2.4.2.1 Orientation
The R82 transmitter utilizes a linearly polarized, microwave
beam that can be rotated to improve its performance. Proper
orientation can minimize unwanted target reflections, decrease
sidewall reflections (multipath) and maximize direct reflec-
tions from the liquid surface.
The internal launcher mechanism can be turned to optimize
performance. The launcher has index marks numbered
1–18 (representing 10–180 degrees). The Polarization
pattern is at 45 degrees to the transmitter display when
the mechanism is at the #9 position.
Figure X
Beam Orientation with #9
Launcher Position
Figure X
R82 Mounted in Stillwell (Bridle)
Ground
Launcher Adjustment
(with #9 Position Selected)
45°
(+)
(-)
45
°