Magnetrol R82 사용자 설명서

다운로드
페이지 48
26
58-610 Model R82 Radar Transmitter
Display
Action
Comment
45
Factory Params
Select Enter to reveal Factory
Parameters; Back to escape.
Review Factory parameters
46
History
Displays history of diagnostic information
- Main screen displays active message
- Press Enter to display chronological listing of diagnostic events
- Use Up/Down arrows to view list of events
- Press Enter when viewing an event to see its timing information
- Press Up/Down arrows to view Occured or Duration
NOTE: All times are in seconds from moment of power up
- Press Back to exit
47
Run Time
Display Run Time
Displays amount of time in seconds since the last power-up.
48
History Reset
Reset History
Press Enter to clear diagnostic information in History and reset
Run Time to zero.
49
System Code
Displays System Code errors Diagnostic, factory setting
50
Electrical Temp
Display Electrical Temperature Displays current temperature on circuit board
51
Max Temp
Display Max Temperature
Displays maximum temperature recorded for circuit board
52
Min Temp
Display Min Temperature
Displays minimum temperature recorded for circuit board
53
VDC Chk Midpoint
None, do not adjust
Diagnostic factory setting
54
Echo Profile
None, do not adjust
Diagnostic factory setting
55
Target Algorithm
None, do not adjust
Diagnostic factory setting
56
TVG Type
None, do not adjust
Diagnostic factory setting
57
TVG Maximum
None, do not adjust
Diagnostic factory setting
58
Peak Detect Ref
None, do not adjust
Diagnostic factory setting
59
Peak Detect Thresh
None, do not adjust
Diagnostic factory setting
60
Min Threshold
None, do not adjust
Diagnostic factory setting
61
# Run Average
None, do not adjust
Diagnostic factory setting
62
Adaptive Filter
None, do not adjust
Diagnostic factory setting
63
# Adap Average
None, do not adjust
Diagnostic factory setting
64
Scatter HiLimit
None, do not adjust
Diagnostic factory setting
65
Rate HiLimit
None, do not adjust
Diagnostic factory setting
66
Scatter Rate
None, do not adjust
Diagnostic factory setting
67
Lvl ROC Per Min
None, do not adjust
Diagnostic factory setting
68
Max ROC Per Min
None, do not adjust
Diagnostic factory setting
69
Max Distance Jump
None, do not adjust
Diagnostic factory setting
70
Boundary State
None, do not adjust
Diagnostic factory setting
71
EmptyState Delay
None, do not adjust
Diagnostic factory setting
72
NSPValue
None, do not adjust
Diagnostic factory setting
73
Factory Calib
None, do not adjust
Diagnostic factory setting
74
Antenna Type
None, do not adjust
Diagnostic factory setting
75
Antenna Extn
None, do not adjust
Diagnostic factory setting
76
Antenna Mount
None, do not adjust
Diagnostic factory setting
77
Window
None, do not adjust
Diagnostic factory setting
78
Target Distance
None, do not adjust
Diagnostic factory setting
79
Conversion Factor
None, do not adjust
Diagnostic factory setting
80
Scale Offset
None, do not adjust
Diagnostic factory setting
81
System Gain
None, do not adjust
Diagnostic factory setting
2.6.5.2 Radar Transmitter Factory Menu