Magnetrol R82 사용자 설명서

다운로드
페이지 48
32
58-610 Model R82 Radar Transmitter
3.3.2 Error Messages
The Model R82 Radar transmitter utilizes a 3-section
hierarchy for reporting diagnostic conditions: FAULTS,
WARNINGS, and INFORMATION. This information
will be shown in the Home screen when the message is
active. A chronological listing of messages can be viewed
in the HISTORY screen.
FAULT: The highest level in the hierarchy of diagnostics
annunciating a defect or failure in circuitry or software that
precludes reliable measurement. The current (mA) value
unit defaults to 3.6, 22, or HOLD and the Home screen
will freeze showing the highest priority Fault. Other Faults
can also be viewed using the UP/DOWN arrows. A chrono-
logical listing of messages can be viewed in the HISTORY
screen.
WARNING (MESSAGE): The second level in the hierar-
chy of Diagnostics annunciating conditions that are not
fatal but may affect measurement. The highest priority
Warning will be placed on the main (rotating) screen when
a Warning is detected but will not affect output current.
Other Warnings can also be viewed using the UP/DOWN
arrows. A chronological listing of messages can be viewed
in the HISTORY screen.
INFORMATION (MESSAGE): The lowest level in the
hierarchy of diagnostic conditions providing operational
factors that are not critical to measurement. A chronological
listing of messages can be viewed in the HISTORY screen
mA Loop
Display Message
History Screen
Fault
3.6/22/HOLD
Yes
Yes
Warning
No Effect
Yes
Yes
Information
No Effect
No
Yes
EFFECTS OF EACH DIAGNOSTIC MESSAGE
 Also listed in History screen are changes of "state". For example, "BC Level" which
means Boundary Condition Level. This is an expression of the transmitter’s internal logic.