Magnetrol R82 사용자 설명서

다운로드
페이지 48
35
58-610 Model R82 Radar Transmitter
3.4
Agency Approvals
FM
R82-52XA-0XX
Intrinsically Safe
Class
I, Div. 1; Groups A, B, C, & D
NEMA 4X, IP 66 T4 @80°C
Entity
R82-52XA-0XX
Non-Incendive
Class
I, Div. 2; Groups A, B, C, & D
NEMA 4X, IP 66
CSA
R82-52XA-0XX
Intrinsically Safe
Class
I, Div. 1; Groups A, B, C, & D
NEMA 4X, IP 66 T4 @80°C
Entity
R82-52XA-0XX
Non-Incendive
Class
I, Div. 2; Groups A, B, C, & D
NEMA 4X, IP 66 T4 @80°C
ATEX
R82-5BXA-0XX
Intrinsically Safe
ATEX
II 1G Ex ia T4 @70°C
Ambient Temp: -40° to +70° C
(EN60079-0: 2007, EN60079-11: 2007
&
EN60079-26: 2007 standards applied
AGENCY
MODEL
PROTECTION METHOD
AREA CLASSIFICATION
These units have been tested to
EN 61326 and are in compliance
with the EMC Directive 2004/108/EC.
COMMUNICATIONS APPROVALS
ATEX Entity Parameters
Region
Agency
Frequency
US
FCC
26 Ghz
Canada
IC
Europe
RTTE
Vi
28.4 VDC
li
120 mA
Pi
0.82 w
Ci
5.5 nF
Li
370
µH
Model R82
SIL
1 as 1oo1
Instrument Type
B
SFF
73.7%
PFDavg
9.72E-04
FITS
Annual
Fail Dangerous Undetected
222
1.94E-03
Fail Dangerous Detected
308
2.70E-03
Safe
314
2.75E-03
NEMA rating: -20 to +80C (Tefzel
®
antenna only)
For Division 2 the measured media inside the vessel must be non-flam-
mable only and the apparatus must be only connected to an inherently
limited power source (Class 2 power supply) as defined in the NEC
table 11
Special conditions for safe use (ATEX Ex i)
 Materials marked as category 1 equipment and mounted in hazardous
areas requiring this category shall be installed in such way that, even in
the event of rare incidents, the aluminum enclosure cannot be an ignition
source due to impact or friction.
 The transmitter shall be installed so that electrostatic discharges on
plastic parts are prevented.
SIL