Sierra Wireless HL7748 사용자 설명서

다운로드
페이지 53
 
41110555 
Rev 1.0 
September 21, 2017 
23 
3.  Detailed Interface Specifications 
Note:  
If not specified, all electrical values are given for VBATT=3.7V and an operating temperature of 25°C. 
 
For standard applications, VBATT and VBATT_PA must be tied externally to the same power supply. 
For some specific applications, AirPrime HL77xx modules support separate VBATT and VBATT_PA 
connections if requirements below are fulfilled. 
3.1. 
Power Supply 
The AirPrime HL77xx modules are supplied through the VBATT and VBATT_PA signals. 
Refer to the following table for the pad description of the Power Supply interface. 
Table 7. 
Power Supply Pad Description 
Pad Number 
Signal Name 
I/O 
Description 
63 
VBATT 
Power supply (base band) 
61, 62 
VBATT_PA  
Power supply (radio frequency) 
37, 39, 48, 67-70, 167-234 
GND 
 
Ground 
 
Refer to the following table for the electrical characteristics of the Power Supple interface. 
Table 8. 
Power Supply Electrical Characteristics 
Supply 
Minimum 
Typical 
Maximum 
VBATT voltage (V) 
3.2
1
 
3.7 
4.5 
VBATT_PA voltage (V) Full Specification 
3.2
1
 
3.7 
4.5 
VBATT_PA voltage (V) Extended Range 
2.8
2
 (TBC) 
3.7 
4.5 
1   
This value must be guaranteed during the burst 
2   
No guarantee of 3GPP performances over extended range 
Note:  
Load capacitance for VBATT is around 37µF ± 20% (TBC) embedded inside the module. 
Load capacitance for VBATT_PA is around 11µF ± 20% (TBC) embedded inside the module.