Product Technical Specification 
Detailed Interface Specifications 
Pad Number 
Signal Name* 
I/O* 
Description 
UART1_CTS 
The AirPrime HL77xx is ready to receive AT 
commands 
UART1_TX 
Transmit data 
UART1_RX 
Receive data 
UART1_DTR 
I (active low) 
Prevents the AirPrime HL77xx from entering sleep 
mode, switches between data mode and command 
mode, and wakes the module up. 
UART1_DCD 
Signal data connection in progress 
UART1_DSR 
Signal UART interface is ON 
*   
According to PC view. 
Note:  
UART1_CTS must be left floating or set to level “0”  before starting the HL77xx module. 
3.9. 
Power On Signal (PWR_ON_N) 
The PWR_ON_N signal is internally connected to the permanent 1.8V supply regulator inside the 
AirPrime HL77xx module via a pull-up resistor. Once VBATT is supplied to the  module, this 1.8V 
supply regulator will be enabled and so the PWR_ON_N signal is by default at high level.  
A low-level signal on PWR_ON_N must be provided to switch the AirPrime HL77xx module ON, and the 
signal must be kept at low level to keep the module ON. 
Refer to the following table for the pad description of the PWR_ON_N interface. 
Table 20. 
PWR_ON_N Pad Description 
Pad Number 
Signal Name 
I/O 
Description 
59 
PWR_ON_N 
Power the AirPrime HL77xx On 
 
Refer to the following table for the electrical characteristics of the PWR_ON_N interface. 
Table 21. 
PWR_ON_N Electrical Characteristics 
Parameter 
Minimum 
Typical 
Maximum 
Input Voltage-Low (V) 
 
0.51 (TBC) 
Input Voltage-High (V) 
1.33 (TBC) 
2.2 (TBC) 
Power-up period (ms) from PWR_ON_N falling edge  
Always set to GND 
PWR_ON_N assertion time (ms) 
25 (TBC)