Sierra Wireless HL7748 사용자 설명서

다운로드
페이지 53
 
 
41110555 
Rev 1.0 
September 21, 2017 
46 
Product Technical Specification 
Reliability Specification (TBC) 
Designation 
Condition 
Component Solder Wettability 
CSW 
 
Standard: JESD22 – B102, Method 1/Condition C, Solderability Test 
Method 
Special conditions: 
 
Test method: Dip and Look Test with Steam preconditioning 8 
h+/-15min. dip for 5 +0/-0.5 seconds 
Operating conditions: Un-powered 
Duration: 1 day 
Moist Heat Cyclic Test 
MHCT 
 
 
Standard: IEC 60068-2-30, Test Db 
 
Special conditions: 
 
Upper temperature: +40 ± 2°C 
 
Lower temperature: +25 ± 5°C 
 
RH: 
 
Upper temperature: 93% 
 
Lower temperature: 95% 
 
Number of cycles: 21 (1 cycle/24 hours) 
 
Temperature Variation: 3 +/- 0.6°C/min 
Operating conditions: Powered ON for 15 minutes during each 3 hours 
ramp up and 3 hours ramp down (in middle) for every cycle 
Duration: 21 days 
6.2.4. 
Thermal Resistance Cycle Stress Tests 
The following tests the AirPrime HL77xx modules’ resistance to extreme temperature cycling. 
Table 42. 
Thermal Resistance Cycle Stress Tests 
Designation 
Condition 
Thermal Shock Test 
TSKT 
 
Standard: IEC 60068-2-14, Test Na 
Special conditions: 
 
Temperature: -30°C to +80°C 
 
Temperature Variation: less than 30s 
 
Number of cycles: 600 
 
Dwell Time: 10 minutes 
Operating conditions: Un-powered 
Duration: 9 days 
Temperature Change 
TCH 
 
Standard: IEC 60068-2-14, Test Nb 
Special conditions: 
 
Temperature: -40°C to +90°C 
 
Temperature Variation: 3 +/- 0.6°C/min 
 
Number of cycles: 400 
 
Dwell Time: 10 minutes 
Operating conditions: Un-powered 
Duration: 29 days