Troubleshooting
9-8
InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620616-0-20 Rev F
9.3.2.2
Troubleshooting Expansion Hub LEDs During Normal Operation
• All of the Expansion Hub 
LINK
 and 
E-HUB/RAU
 LEDs that have RAUs connected 
should be Green/Green, indicating that the RAU is powered on, communication is 
established, and operation is normal.
• The 
POWER
,
 EHUB STATUS
DL STATUS
, and
 UL STATUS 
LEDs should all be Green.
Table 9-3
Troubleshooting Expansion Hub Port LEDs During Normal 
Operation
During
Normal 
Operation
Expansion 
Hub Port 
LEDs
State
Action
Impact
RAU is not 
connected
PORT
Off
If the RAU was disconnected acci-
dentally, re-connect the CATV 
cable. The Expansion Hub’s port 
LEDs should change to Green/Red 
(then Green/Green, after 20 sec-
onds, if the Main Hub is connected, 
powered on, and has band pro-
grammed).
Use AdminBrowser’s “Clear All 
Disconnect Status” command if 
you are permanently removing the 
RAU from service. The Expansion 
Hub’s port LEDs should change to 
Off/Off.
The RAU was previously connected, 
but it is not currently connected; the 
RAU cable is disconnected.
RAU is 
connected
PORT
Red
Disconnect/reconnect the CATV 
cable to force power-on reset to the 
RAU. If the port LEDs remain Red 
check for the exact cause of Expan-
sion Hub faults using Admin-
Browser.
Lost communications with the RAU. 
The RAU could have powered down 
due to over current; cable could have 
been damaged.
PORT
Flashing 
Red (60 
ppm)
The RAU reports a fault condition; 
check for the exact cause of Expan-
sion Hub and RAU faults using 
AdminBrowser.
Depends on the fault condition.
PORT
Flashing 
Red (60 
ppm)
The Expansion Hub reports no con-
nection, cable shorts, or a current 
port trap condition.
Expansion Hub communications with 
the RAU. The Expansion Hub is at 
fault. The cable could have been dam-
aged. The cable leads may be shorted.