ADC Telecommunications Inc. F0684-112 사용자 설명서

다운로드
페이지 236
C-16
InterReach Fusion Wideband Installation, Operation, and Reference Manual
 CONFIDENTIAL
D-620616-0-20 Rev F
C.7
Messages for Expansion Hubs
Table C-7
Warning/Status Message for Expansion Hubs 
Message 
Number 
/Default
Description
Reason/Action
[E01]/W
Alarm Input 1.
Check the equipment connected to alarm input 1.
[E02]/W
Alarm Input 2.
Check the equipment connected to alarm input 2.
[E03]/W
Alarm Input 3.
Check the equipment connected to alarm input 3.
[E04]/S
Problem detected in the EH.
Contact TE Support for more information.
[E05]/W
SNMP Trap #1.
TBD.
[E06]/W
SNMP Trap #2.
TBD.
[E07]/W
SNMP Trap #3.
TBD.
[E08]/S
Problem detected in the EH.
Contact TE Support for more information.
[E09]/S
Fan 1 failure.
Check the fan for proper rotation, air flow blockage, and dust 
accumulation. Replace the Hub on high temperature warning.
[E10]/S
Fan 2 failure.
Check the fan for proper rotation, air flow blockage, and dust 
accumulation. Replace the Hub on high temperature warning.
[E11]/W
-5 VDC Monitor.
DC power out of range, replace the Hub.
[E12]/W
5 VDC Monitor.
DC power out of range, replace the Hub.
[E13]/W
9 VDC Monitor.
DC power out of range, replace the Hub.
[E14]/W
54 VDC Pwr Supply failure.
DC port power supply out of range, replace the Hub.
[E15]/W
3 VDC Monitor.
DC power out of range, replace the Hub.
[E16]/W
12 VDC Monitor.
DC power out of range, replace the Hub.
[E17]/W
Temperature High.
Reduce the ambient temperature, check for air flow blockage, 
fan rotation.
[E18]/W
DL path exceeds maximum gain.
If the problem is common to more than one port, replace the 
MH, otherwise check the EH.
[E19]/W
DL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different MH port. If the problem is on more than 
one port, replace the EH, otherwise replace the RAU.
[E20]/W
Hardware Failure (High UL 
Pilot).
Cycle power once. If the fault persists, replace the EH.
[E21]/W
Hardware Failure (Low UL 
Pilot).
Cycle power once. If the fault persists, replace the EH.
[E22]/W
Low optical input power.
Check the downlink fiber connection.
[E23]/W
High laser current.
Contact TE Support for more information.
[E24]/S
Problem detected in the EH.
Contact TE Support for more information.
[E25]/W
Port 1 No DL test tone (Band 1).
Hub/Port DL path gain is low.
[E26]/W
Port 2 No DL test tone (Band 1).
Hub/Port DL path gain is low.
[E27]/W
Port 3 No DL test tone (Band 1).
Hub/Port DL path gain is low.
[E28]/W
Port 4 No DL test tone (Band 1).
Hub/Port DL path gain is low.
[E29]/W
Port 5 No DL test tone (Band 1).
Hub/Port DL path gain is low.
[E30]/W
Port 6 No DL test tone (Band 1).
Hub/Port DL path gain is low.
[E31]/W
Port 7 No DL test tone (Band 1).
Hub/Port DL path gain is low.
[E32]/W
Port 8 No DL test tone (Band 1).
Hub/Port DL path gain is low.