ADC Telecommunications Inc. F0684-112 사용자 설명서

다운로드
페이지 236
Expansion Hub Specifications
4-10
InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620616-0-20 Rev F
4.5
Expansion Hub Specifications
Table 4-4
Expansion Hub Specifications
Specification
Description
Enclosure Dimensions (H 
 W 
 D)
89 mm x 438 mm x 381 mm 
(3.5 in. x 17.25 in. x 15 in.) 2U
Weight
< 6.6 kg (< 14.5 lb.)
Operating Temperature
0° to +45°C (+32° to +113°F)
Non-operating Temperature
–20° to +85°C (–4° to +185°F)
Operating Humidity, non-condensing
5% to 95%
CATV Connectors
a
a. It is important that you use only recommended CATV 75 Ohm cable with quality F connectors.
8 F, female (CATV - 75 Ohm)
Fiber Connectors
b
b. It is critical to system performance that only SC/APC fiber connectors are used throughout the fiber network, including 
fiber distribution panels.
1 Pair, SC/APC
LED Alarm and Status Indicators
Unit Status (1 pair):
• Power
• E-Hub Status
Fiber Link Status (1 pair):
• DL  Status
• UL  Status
Port Status (1 pair per CATV port):
• Link/RAU
External Alarm Connector (contact sense 
monitor)
1 9-pin D-sub, female
AC Power (Volts) (47–63 Hz)
Rating: 100/240V AC, 6A, 50-60 Hz
Operating Range: 90-132V AC/170-250V AC auto-ranging
Power Consumption (W)
4 RAUs: 275 typical, 335 max.
8 RAUs: 475 typical, 585 max.
MTBF
54,539 hours