Elpas Solutions Ltd. 5-LWA00433 사용자 설명서

다운로드
페이지 4
Elpas Lone Worker Transmitter 
– User Guide 
 
 
 
www.elpas.com
 
Page 2 of 4 
V5/June 2013
 
 
 
Initial Activation & Software Enrollment 
The  Lone  Worker  Transmitter  is  shipped  from  the  factory  in  
Sleep Mode
 to conserve battery power during transit. 
 
1. Prior  to  initial  usage,  remove  the  Activation  Label  and  then 
press  simultaneously  both  of  the  Tag’s  emergency  call  push 
buttons for at least 7 seconds. 
 
This action serves as a means of Awakening the Transmitter from 
Sleep  Mode  as  well  as  enrolling  its  unique  factory  installed  
ID  Number  (
a six-digital hexadecimal value) into the Host RTLS 
Application. 
If  the  Enrollment  process  was  successful  the  Transmitter’s 
Red LED Status Indicator will alight for 3 seconds.  
(
Refer to your Eiris Configuration Guides for additional details.) 
Battery Replacement 
1. Temporarily  suspend  usage  of  the  Transmitter  in  the  host 
RTLS application. 
2. Place the transmitter on its right side. Remove the 2 screws 
that holds the battery cover to the body of the Transmitter 
 
3. Utilize the pull tab to slide the battery out of the Transmitter 
from the battery Dispose of the used battery in accordance 
with local regulations. 
  CAUTION!  After  removing  the  battery  please  wait  at 
least 30 seconds before installing the replacement battery 
so as to not cause damage to the tag or to negatively affect 
the tag’s operational performance
4. Before  inserting  a  new  battery  into  place,  Place  a  new 
Battery Pull Tab onto the (+) positive side of the battery. 
 
5. Slide the battery back into the transmitter.  
  IMPORTANT!  Ensure  that  the  positive  (+)  side  of  the 
battery faces up and that the pull tab is fully accessible. 
6. Close the side-cover such that the screw holes are correctly 
aligned. Tighten the 2 screws snugly into place. Do not over-
tighten as this may strip the case threads. 
7. Reactive the Transmitter in the Host RTLS Application. 
 
Safety Issues 
It  is  the  responsibility  of  the  system  installer  to  ensure  that  the 
appropriate staff members are suitably trained in the usage and 
maintenance of the Lone Worker Transmitter. 
Additionally, Supervisory Alerts should be configured in the Host 
RTLS  Application  to  notify  staff  members  that  the  detection 
Transmitter is:  
  In a low battery condition or  
 
Not properly transmitting location and status data. 
 
Note:
  The  above  configured  Supervisory  Alerts  should  be  triggered 
periodically to ensure system integrity. 
 
Alert Testing  
Pressing  either  the  left  or  right  emergency  call  push-button 
individually will trigger the Lone Worker Transmitter to emit a Test 
Alert Message so that the host RTLS application can confirm that 
the unit is functioning properly. 
 
Preliminary_V5