Page 17
+01 Unit ID: 01
+02 Freq: 458600000
+03 RX Mode: A512
+04 Relay Monoshot: 0
+05 RIC Range 1: 1234567,1234567
+06 RIC Range 2: 0000000,0000000
+07 RIC Range 3: 0000000,0000000
+08 RIC Range 4: 0000000,0000000
+09 Store Forward Mode: 0
+10 WDog Timeout: 0
+11 In Debounce: 4
+12 In Tx Count: 1
+13 In Resend Delay: 5
+14 In 1 Hi Msg: CA1234560 1 Input 1 High
+15 In 1 Lo Msg: None
+16 In 2 Hi Msg: None
+17 In 2 Lo Msg: None
+18 WDog Msg: None
+19 Serial Mode: 1
Unit ID:   The unit ID is used to uniquely address a unit to control outputs.  The unit ID
must be 2 characters.  If numeric decoding is specified, then the unit ID must be
between 00 and 99.  If alphanumeric decoding is used then any printable character can
be used as part of the unit ID allowing for approximately 8000 possible addressing
codes.  The unit of ‘00’ can also be set, but is also used as a group address code.
Typical usage:  +01=01<CR>
Freq:  This is the receive and transmit frequency.  This parameter should be
programmed to be between 440000000 and 479000000 and must be specified in Hz. .
Typical usage:  +02=458600000<CR>
Mode:  The mode primarily determines the receiver mode of operation.  Possible
settings are A512, A1200, N512 or N1200. ‘A’ specifies alphanumeric operation.  ‘N’
specifies numeric operation.  512 and 1200 specifies the receiver decode baud rate.
Typical usage:  +03=A512<CR>
Relay Mono-shot:  If specified, the mono-shot will open the relay after the relay has
been closed for the configured monoshot period. Setting the relay to 0 results in latched
operation (mono-shot timer not operating).  The timer can be set in 1 second
increments to a maximum of 65535 (approx 18 hours). When configured, timeout is
rounded up to closest second (setting to 1 second will result in a mono-shot of 1-2
seconds).
Typical usage:  +04=0<CR>
RIC Range:  Up to 4 receiver decode ranges can be specified.  If all 4 RIC ranges are
set to 0, the unit will not operate as a receiver.  The first parameter of each range, when
non zero, must not be greater than the second parameter.  Each parameter should be
between 0000008 and 2000000.  All 7 digits must be specified.  The first and second
parameter can be set to the same code if only a single code is required.
Typical usage (to decode all messages for addresses between 1234560 and 1234567):
+05=1234560,1234567<CR> 
Store Forward Mode:  When set to 1 the store forward repeater operation is enabled. 
In this mode of operation a 40 second duplicate message reject timer is enabled.  All
received messages are immediately queued for re-transmission when the channel is
not busy.  
In this mode each transmission is timed, preventing the transmission of any newly
SALCOM 12-90 PAGING TRANSCEIVER AND STORE FORWARD REPEATER        Issue 1290UB 0211
Sea Air and Land Communications Ltd
Page 18
queued messages until a period equal to the last transmission has elapsed (to give any
downstream repeaters a chance to pass the message on again).  In store forward mode
a pre-transmission delay is applied that varies based on unit ID.