Honeywell International Inc. CX85WCR 사용자 설명서
Part Replacement Procedures
6-19
DIAD 6 Charge Rack Manual
I/O Board Cable - 50142485-001FRE
I/O Board Cable - 50142485-001FRE
Part Name:
I/O Board Cable
Part #:
50142485-001FRE
Tools Required:
1 medium #2 Phillips head screw driver
Before working on the Charge Rack, always disconnect the AC cord from the power
supply.
After removing power, wait 15 minutes before servicing the unit to avoid shock.
1. Remove the 6-slot bay from the Charge Rack.
2. There are 6 cables on the 6-slot bay. Disconnect the broken one and replace it with the new
cable.
3. Reload the 6-slot bay into the Charge Rack.
Do not pinch wires during reinstallation as this may damage the equipment
Be careful not to over-tighten the screws, which could damage the 6-Slot Bay and prevent
the component from being adequately secured.
the component from being adequately secured.