Search Platform Detectors assembly  
3.1 
Typical Module installation  
Following guide shows typical installation of the module: 
Figure 2 shows Searchzone Sonik 
– one member of the SPD family with section the Main body, which contains 
Wireless module and carries antenna.  
 
Figure 2: Search Platform Detectors main sections (Searchzone Sonic on picture) 
 
 
SPWM is attached to one of the 2 PCAs in the main body (PSU2 
– power supply unit). The figure number 3 
captures exploded view of the Main section of detector and how the wireless module is connected to it. This 
example shows Searchzone Sonik which is one example of the Search Platform Detectors (SPD). Construction 
of the Main body is same for all family products, therefore assembly process of Wireless module is the same.     
 
Connection between PSU2 PCA and wireless module uses 40 pins connector. The plastic standoff clips are 
used for support and vibration stability on 3 edge points of the 
SPWM’s PCB. During the assembly, wireless 
module is connected first to PSU2 PCA, then preinstalled antenna cable, which sticks out of the Main body is 
connected to only wireless MMCX antenna connector of SPWM. Length of cable is 94mm. PSU2 is inserted with 
SPWM into the Main body.     
 
Connection between antenna and SPWM module includes 2 components. Antenna coupler and antenna cable. 
For the reason of detector to operates in explosive area, the impedance matched, isolating AC coupler 
(capacitance) is present at the interface between the Main body and the external placed antenna. Antenna 
coupler has shape of screw with MMCX connector from the interior for antenna cable and exterior RP-SMA 
Female connector for antenna.