Nortek Security & Control LLC/GTO Access SGER 사용자 설명서

다운로드
페이지 2
SENSE INPUT
SENSE POWER
M1
+
M2
Closed
Open
GND
SENSE
Gate Edge
Controller
DC Operator
LEARN 1
LEARN 2
3.3V
GND
The pushbutton labeled LEARN 2 is used to program transmitters to channel two. Momentarily press the receiver’s program button. The 
red programming LED will light. The LED slowly blinks 
for about 60 seconds. A transmitter must be entered 
while the LED is on. Press the desired learn button. The 
LED will flicker indicating that the receiver has accepted 
the transmitter and channel relay will toggle.
NOTE: Be sure to press the receiver program button 
for less than 2 seconds.
Be sure gate area is clear. Test the units by activating the gate and touching the 
edge sensor to ensure the gate obstructs.
Transmitters may be erased from the receiver’s memory by pressing and holding 
the receiver’s program button until the LED blinks one time as the receiver’s 
memory is erased. Then release the program button.
This Linear PRO Access (LPA) product is warranted against defects in material 
and workmanship for twelve (12) months. The Warranty Expiration Date is labeled 
on the product. This warranty extends only to wholesale customers who buy direct 
from LPA or through LPA’s normal distribution channels. LPA does not warrant 
this product to consumers. Consumers should inquire from their selling dealer as 
to the nature of the dealer’s warranty, if any. There are no obligations or liabilities 
on the part of LPA for consequential damages arising out of or in connection with 
use or performance of this product or other indirect damages with respect to loss 
of property, revenue, or profit, or cost of removal, installation, or re-installation. 
All implied warranties, including implied warranties for merchantability and implied 
warranties for fitness, are valid only until Warranty Expiration Date as labeled on 
the product. This LPA Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Product Authorization 
Number (RPA#). Contact LPA Technical Services at 1-800-543-1236 for an 
RPA# and other important details
Linear PRO Access radio controls provide a reliable communications link and fill an 
important need in portable wireless signaling. However, there are some limitations 
which must be observed.
PRINTERS INSTRUCTIONS 
 INSTR,INSTL,SGER SERIES - GTO P/N: 
10016916
 - INK:  BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” -  SCALE: 1-1 - SIDE 2 of 2
LEARN 1
LEARN 2
CHANNEL TWO
PUSHBUTTON 
USE THIS
PUSHBUTTON
TO ENTER A
TRANSMITTER
INTO CHANNEL
TWO
 
LEARN 2
LEARN 1
S2
PRESS THE TRANSITTER
BUTTON ON THE CONTROL
BOARD
PRESS THE LEARN 
BUTTON FOR THE 
DESIRED CHANNEL
(LEARN 1 or LEARN 2)
THE LED WILL 
LIGHT AND REMAIN 
ON ABOUT FIVE 
SECONDS
RECEIVER LED WILL FLICKER
AS TRANSMITTER IS ENTERED
INTO MEMORY 
LEARN 1
LEARN 2
LED WILL FLASH, COUNTING 
THE TOTAL NUMBER OF 
TRANSMITTERS PROGRAMMED. 
THEN IT WILL BLINK ONCE 
(CHANNEL ONE) OR TWICE 
(CHANNEL TWO) AS THE 
TRANSMITTERS ARE ERASED.
PRESS PROGRAM BUTTON FOR 
FIVE SECONDS OR MORE
STEP 6b     Connect antenna
STEP 7     Program the receiver
STEP 8     Test receiver
INFO 1     Erasing receiver memory
Troubleshooting
LIMITED WARRANTY
IMPORTANT
 
TOUCH THE EDGE 
SENSOR TO ENSURE 
THE GATE OBSTRUCTS
WARNING: BE SURE GATE AREA IS 
CLEAR OF OBSTRUCTIONS
Copyright© 2017 GTO Access Systems, LLC
Document Number:  10016916 REV A (05-15-17)
SGER 
Alarm  Fault?   Condition
 Code
Low Batt  1 
NO 
Low Battery 
Open 
YES 
No resistance across TB1 and TB2 of SGET
No Ack 
YES 
SGET not able to send message 
 
 
 
(dead or too far away)
Edge 
YES 
Edge shorted
DC Operator Wiring
NOTE: For AC Operator install an AC 
Sensor, and refer to the AC Sense 
instructions book. 
WARNING: Changes, modifications or adjustments not expressly approved by GTO 
Access Systems, LLC could void the user’s authority to operate this equipment. 
There Are No User Serviceable Parts.
NOTICE: This device complies with part 15 of the FCC rules and with Industry 
Canada license-exempt RSS standard(s). Operation is subject to the following two 
conditions: (1) this device may not cause interference, and (2) this device must 
accept any interference, including interference that may cause undesired operation 
of the device
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux 
appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions 
suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de 
l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est 