Applied Concepts Inc ACMI007 사용자 설명서
Applied Concepts 011-0131-00 rev 2
Page 39
7.2 Changing and Saving the Configuration
The settings in the Speed Sensor can be changed by selecting other values from the
settings’ pull-down menus as shown below, for example, changing the units from MPH to
km/H (Kilometers per Hour). Click the Options Menu and select the Upload Proposed
Values to Sensor to save the settings changes to the Speed Sensor. The changes can
be confirmed by observing that the Sensor Values are now equal to the Proposed
Values.
settings’ pull-down menus as shown below, for example, changing the units from MPH to
km/H (Kilometers per Hour). Click the Options Menu and select the Upload Proposed
Values to Sensor to save the settings changes to the Speed Sensor. The changes can
be confirmed by observing that the Sensor Values are now equal to the Proposed
Values.
When Upload Proposed Values to Sensor button is clicked, the Stalker Dashboard
application sends separate commands to the Speed Sensor to set each value. The
Speed Sensor responds to each command with its new or current setting value. The
new settings are stored in the Speed Sensor’s internal memory and are remembered
even when the unit is turned off and back on.
If the Speed Sensor responds to the application with a value different from the desired
value, an error may be seen as shown below. This example shows many errors due to
the fact the unit was turned off.