Charles Machine Works Inc The 2150GRDUO 사용자 설명서

다운로드
페이지 43
2150GR Ground Penetrating Radar 
054-140 - Rev. 2
 
 
7/36 
3.1.3 Power supply 
The Control Unit is powered by a lead 12V, 12Ah battery. 
 
Lead Battery 
 
3.1.3.1 Charge level and battery replacement 
When the indicator next to the power supply port lights, the system is powered. If the 
indicator does not light, either the cable is not connected correctly or the battery needs 
recharged (less than 10V). The battery has a useful life of about 12 hours. When the 
battery runs down, turn off the unit, connect another battery, and restart the system. Allow 
approximately 3 hours to recharge the battery. Use an appropriate battery charger.  
The battery status is indicated in the software window: 
¾  Green if the battery is fully charged 
¾  Yellow if it is semi-charged 
¾  Red if the battery needs recharged 
 
   
Battery status signal (left) and battery charger (right) 
 
 
NOTE
 
 
The control unit continuously draws current from the battery. To prevent 
drain, unplug the battery when the unit is not in use.