Wiring and Installation Instructions PRM 5
Calculation of the parity:
LRC = 80h OR [52h Å 45h Å 30h Å 43h Å 35h Å 35h Å 37h Å 30h] = E3h
(‘‘Å’’ means Exlusive-OR)
5 Installation
5.1
PRM 5 Reader
The PRM 5 reader can be surface mounted using an AP 5 spacer, or flush mounted direct to an European
round style back box.
Flush mounted with FM5 bezel
Flush mounted directly with a
Surface mounted with AP5 spacer
European round back box