3. If the EPIRB fail to end up with a continuous light, this indicates a fault in the EPIRB.
4. Release the switch and put the EPIRB back into the bracket.What the self test actu-
ally does is first to wait app. 15 seconds to allow the reference oscillator inside the
EPIRB to warm up.Then a short burst is transmitted by the 121.5 MHz transmitter,
while the output level of the transmitter is checked. Finally, a test signal is transmitted
by the 406 transmitter. During this test signal the battery voltage, output power and
frequency is checked.
While testing the 406 MHz transmitter a test message is transmitted, this test message
is coded with a special synchronisation code and will not be detected by the COSPAS/
SARSAT satellites.The purpose of this test message  is to control the actual coding of
the EPIRB.This can be done with the  JOTRON test unit TronDEC/UniDeck or an other
EPIRB checker.
4. TECHNICAL DESCRIPTION EPIRB TRON 40GPS
4 . 1   F E A T U R E S
•  Watertight:
Tron 40GPS is watertight to a depth of minimum 10 meter.
• Buoyant:
Tron 40GPS is buoyant .
• Rugged design:
The Tron 40GPS will withstand a drop from 30 meters into the water.
It is resistant to seawater, oil and sunlight.
• Handling:
The Tron 40GPS is made for easy operation, with a brief operating 
instruction printed on the unit.
It comes standard with a 20 meter rope that can be attached to the liferaft.
• Indicators:
The Tron 40GPS is equipped with a LED and a built in strobe light to show operation
of the EPIRB.
The strobe light and LED will normally flash with a frequency of 20 per minute to
show that the EPIRB is activated.
4 . 2   S T O R A G E
The EPIRB is normally stored in its bracket.The bracket contains means to prevent acci-
dental activation of the EPIRB.The bracket should be mounted 
in a place that is easily available for periodic testing, and a place which is easily accessible
in case an emergency situation occur.