Yaesu Musen Co. Ltd. 20251X50 사용자 설명서

다운로드
페이지 133
 
FT-2000 
Operating Manual 
Vertex Standard Co., Ltd. 
108
tyP1:  You may enter the CW message from a front panel’s Function Keys (require the 
optional DMU-2000 Data Management Unit). 
tyP2:  You may enter the CW message from the CW keyer. 
 
024 tEy CW MEM5 
Function: Permits entry of the CW message for message register 5. 
Available Values: tyP1/tyP2 
Default Setting: tyP2 
tyP1:  You may enter the CW message from a front panel’s Function Keys (require the 
optional DMU-2000 Data Management Unit). 
tyP2:  You may enter the CW message from the CW keyer. 
 
GENERAL Group 
025 GEnE ANT SEL 
Function: Sets the method of antenna selection. 
Available Values: bAnd/rEG 
Default Setting: bAnd 
bAnd: 
The antenna is selected in accordance with the operating band. 
rEG: 
The antenna is selected in accordance with the band stack (different 
antennas may be utilized on the same band, if so selected in the band stack). 
 
026 GEnE BEP LVL 
Function: Sets the beep level. 
Available Values: 0 ~ 255 
Default Setting: 50 
 
027 GEnE CAT BPS 
Function: Sets the transceiver’s computer-interface circuitry for the CAT baud rate to 
be used. 
Available Values: 4800/9600/192H(19200)/384H (38400) bps 
Default Setting: 4800 bps 
 
028 GEnE CAT TOT 
Function: Sets the Time-Out Timer countdown time for the CAT command input. 
Available Values: 10/100/1000/3000 msec 
Default Setting: 10 msec