7
2.4  Alarms Displayed While Armed Option
You can disable the display of alarms on the keypad when the system is armed. The
display of alarms is enabled by default. To disable the display of alarms when the
system is armed, turn off section [6], option [5]:
1. Enter [*][8][Installer’s code]
2. Enter [000] to go to keypad programming
3. To turn the display of alarms on or off, enter section [6].
4. Turn option [5] on or off:
[5]
ON = Alarms not displayed while system is armed
OFF = Alarms are always displayed while system is armed
5. When you are finished, press [#] to exit.
2.5  Emergency (Fire, Auxiliary, Panic) Key Options
You can enable or disable the Fire, Auxiliary and Panic keys at each keypad. These
keys are enabled by default. Please see your system’s 
Installation Manual for more
information on these keys and their options. To turn any of the emergency keys on or
off on the keypad:
1. Enter [*][8][Installer’s code]
2. Enter [000] to go to keypad programming
3. Enter section [7].
4. To turn the emergency key options on or off, press [1], [2], or [3]:
[1]
ON = Fire key enabled
OFF = Fire key disabled
[2]
ON = Auxiliary key enabled
OFF = Auxiliary key disabled
[3]
ON = Panic key enabled
OFF = Panic key disabled
5. When you are finished, press [#] to exit.
2.6  Door Chime Options
You can program the RF5501-433 keypad to sound a tone when any zone is opened
or closed. There are two parts to the RF5501-433 door chime programming:
• Program if the RF5501-433 will chime when zones are opened and/or closed.
• Program the type of sound the RF5501-433 will make when an individual zone is opened
or closed.
For the door chime feature to work, you will also need to turn on the Door Chime attribute
for each zone that will trigger the chime. This programming is done in the control panel
software. Refer to your control panel’s 
Installation Manual for more information.
Door Chime on Zone Openings/Closings
You can program each RF5501-433 keypad to sound a door chime when zones are
opened and/or when they are closed. By default, RF5501-433 keypads are programmed to
sound door chimes on both zone openings and closings.
To change the door chime opening/closing settings, at each RF5501-433 keypad:
1. Enter [*][8][Installer’s code]
2. Enter [000] to go to keypad programming
3. Enter section [6].
4. To turn the options on or off, press [6] or [7]:
K E Y P A D  P R O G R A M M I N G