Digital Security Controls Ltd. 12TR5164 사용자 설명서

다운로드
페이지 23
7
4. After successful confirmation of the ESN, the system prompts for the zone/slot number.
• The next available slot for the device type is displayed. Press [
,
] to accept or enter the slot 
number. 
• To re-enroll a wireless key press  simultaneously for approximately 3 seconds.
3.4 Manually Enroll Wireless Devices/Keypads
To manually enroll a 2-way wireless device:
1. Enter [
,
][8][Installer Code][804].
2. Enter the 3-digit zone/slot corresponding to the device type:
Wireless sensors, pendants and repeaters
[804][001]-[064]  (excluding [029]-[032])
Wireless Key
[804][101]-[116] for wireless key numbers 01- 16
Wireless Keypad
[804][029]-[032]
Hardwired and wireless devices cannot be assigned to the same zone. PC5108 zone expander 
modules occupy zones in 2 groups of 4 (e.g., zones 9-12 and zones 13-16). None of the zones 
assigned to a PC5108 module may be used for wireless devices. For more information on zone 
assignment, consult the system Installation Manual.
A wireless key can only be assigned to one partition (partition 1 by default). To assign keys to a 
3. Enter the device serial number. The entry must be 8 digits. For devices with 6-digit serial 
numbers, enter 00 first. Serial numbers include hexadecimal digits. To toggle between decimal 
and hexadecimal values, press [
,
]. For instructions on programming hexadecimal numbers, see 
the system Installation Manual. The device is now enrolled on the system.
4. Record the serial number and the assigned zone number in the programming worksheets in the 
back of this manual.
5. Continue with steps 3 - 5 until all wireless devices are enrolled. 
6. Press [#] to exit.
NOTE: Zone and partition programming must be completed for the wireless devices to 
operate correctly (see Section 4.1, page 8).
NOTE: (For non-UL listed installations) For Repeaters and Wireless Keypads, non-alarm 
zone type 26 is recommended. With this zone type, loss of AC or a Low battery condition 
are not reported to the central station. The alarm panel does not show a trouble for the zone 
but will indicate it as open. Select the Force Arm attribute for this zone. Program a zone 
label to identify the WS4920 or WT5500. E.g., "Rptr 1 Pwr Trbl."
NOTE: (For UL listed installations) If AC loss and low battery must be reported to the 
central station, use a 24-hour zone type. Ensure the Audible attribute is set to Silent. 
To delete a wireless device:
1. At a system keypad, enter [
,
][8][Installer code].
2. Enter programming section [804].
3. Enter the 3-digit number corresponding to the zone you want to remove the device from.
4. Program the ESN as [00000000]. The device is deleted.
5. Press [#] to exit.
8 for more information.
DRAFT