[005] System Toggle Options
[1] Ethernet Receiver 1 Supervised
Default (OFF)
(TL2553G only).
ON: Ethernet Receiver 1 will be supervised and heartbeats will be sent to Ethernet Receiver 1
based on the supervision interval programmed in Section [004].
OFF: Ethernet Receiver 1 will not be supervised. When disabled, heartbeat 1 is sent to the
Ethernet receiver once every hour, regardless of supervision type (heartbeat 1 or 2). The
heartbeat is resent every 5 seconds until ACK. If no event or heartbeat ACK is received after
(Receiver Supervision Interval + 75 seconds), Supervisory trouble is indicated.
NOTE: Ethernet Receiver 2 can not be supervised.
[2] Cellular Receiver 1 Supervised
Default (OFF)
ON: Cellular Receiver 1 will be supervised and heartbeats will be sent to Cellular Receiver 1
based on the supervision interval programmed in Section [004]. If ACK to heartbeat is not
received, it is retransmitted every 5 seconds. Failure to ACK 2 consecutive heartbeats will reset
the radio.
OFF: Cellular Receiver 1 will not be supervised. When disabled, heartbeat is not sent to the
receiver. Supervisory trouble is indicated.
NOTE: Cellular Receiver 2 can not be supervised.
[3] Supervision Type
Default (OFF)
ON: Heartbeat 1 (Commercial Supervision). This supervision type is suitable for applications
where swap detection is required on the supervisory packet.
OFF: Heartbeat 2 (Residential Supervision). This supervision type is suitable for applications
where supervision of the communication path to the receiver is required. (no swap detection).
NOTE: Commercial supervision is more data intensive than residential supervision and should 
only be used when required to meet the approval for the installation.
[4] Primary Path
Default (OFF - TL2553G) (ON - LE2077)
ON: Cellular channel is the primary path. Ethernet channel is the secondary path, if it exists.
OFF: Ethernet channel is the primary path in a dual Communicator. Cellular channel is the
secondary path.
[5] Redundant Communications 
Default (OFF) (TL2553G only)
ON: Events will be communicated to Ethernet Receiver 1 and Cellular Receiver 1 at the same
time. Events will be communicated to Ethernet Receiver 2 and Cellular Receiver 2 at the same
time. As long as the event is successfully communicated to 1 of the 2 paths (Ethernet or
Cellular) the Communicator will move on to the next event.
NOTE: Do not configure Ethernet Receiver 1 and Cellular Receiver 1 to communicate using a 
common receiver configuration (i.e., identical Receiver IP address and Receiver Remote Port). 
OFF: Events will be communicated to the receivers individually.Toggle should be OFF when 
guaranteed message delivery to both receivers is required. 
[6] Remote Firmware Upgrade
Default (ON)
ON: The Communicator module firmware can be remotely upgraded using the Ethernet/
Cellular paths.
OFF: The Communicator module firmware can not be remotely upgraded. Local firmware
upgrade is still possible.
[7] Alternate Test Transmissions
Default (OFF).
ON: When the periodic test transmission interval occurs, the test transmission will alternate
between being sent to the primary and secondary receivers with each test transmission
interval.