ADC Telecommunications Inc. PRSMAW4A 사용자 설명서

다운로드
페이지 138
Viewing RF Band Alarm Details
FlexWave Prism Host, Remote and EMS 5.1 System Reference
Page 253
ADCP-77-073
  • Issue 2 • 11/2009
© 2009 ADC Telecommunications, Inc.
2
2
Click on a 
DART
 band in the RF Groups view (upper link) to open the 
Alarm Details 
of DART-
n
 of Group
 n 
on Remote-
n window.
The
Alarm Details of DART-
n
 of Group
 n 
on Remote-
n window has the the following 
components. For corrective actions for alarm states, refer to 
“Troubleshooting
Alarms” on page 264
.
DART Major Alarms
DART  Fault
—Summary alarm state of the DART card upconverter 
downconverter and the DART FPGA. Red indicates that either the clock 
source for the DART card is outside the acceptable range or the DART FPGA 
is not programmed. 
DART DC Supply Fault
—Red indicates DART card DC supply is faulted. 
DART  Hardware  Mismatch  Fault
—Red indicates an invalid passband 
configuration for the DART. 
DART  Over  Temperature  Fault
—Red indicates DART card internal 
temperature is too high. Fault threshold is 
84°C
.
DART  Remote  Ranging  Fault
—Red indicates that the Host is unable to 
implement the signal delay entered in the RF Band Configuration Page 
(described in 
“Link the Host and Remote DARTs.” on page 159
).
Power Detector Major Alarms
System  VSWR  Fault
—Red indicates a VSWR fault at the interface to the 
antenna (greater than 3:1).
RF Power Fault
—Red indicates that the RF power measured at the antenna 
output is too low. The threshold for this fault is 
0 dBm
.