Troubleshooting Alarms
FlexWave Prism Host, Remote and EMS 5.1 System Reference
Page 269
ADCP-77-073
  • Issue 2 • 11/2009
© 2009 ADC Telecommunications, Inc.
RmtLPALoopFault
Major
The feedback loop 
inside the LPA is not 
working. Causes RF 
mute
Lower DART(s) 
remote gain by 10dB, 
reset the LPA, then 
return gain to values 
previously 
configured. If fault 
persists, replace RF 
Module.
RmtLPALowPowerFault
Major
Internal low power 
fault state of linear 
power amplifier (the 
gain of one or more 
internal amplifiers 
does not meet 
specification). 
Causes RF mute
Reset LPA. If error 
persists, consult 
ADC, replace RF 
Module
RmtLPAOverPowerFault
Internal over power 
fault state of linear 
power amplifier 
(power level is high 
enough to damage 
LPA)
Reduce FWD gain, 
reset the LPA, and 
then monitor power 
levels. Adjust gain to 
acceptable values. 
Reset LPA. If error 
persists, consult 
ADC, replace RF 
Module
RmtLPAVswrFault
Major
Internal VSWR fault 
state of linear power 
amplifier (greater 
than 3:1). Causes RF 
mute
Reset LPA. If error 
persists, consult 
ADC, replace RF 
Module
RmtMajorExtAlarmInputFault
Major
External major alarm 
contact input
Not used
RmtMinorExtAlarmInputFault
ALARM-
TYPE 
(Minor,
OK) 
External minor alarm 
contact input
Not used
RmtModuleMissingFault
Major
One of the pluggable 
modules is missing 
on the Remote
Replace or 
decommission the 
missing module
Table 11-1.  EMS Alarm Descriptions and Corrective Actions (Cont.)
Alarm Name
Alarm 
Severity 
Level
Description
Action