Managing Host Units
Page 218
FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc
ADCP-77-073
  • Issue 2 • 11/2009
2
2
(Optional) To enlarge the view, click Full Screen to open a separate window that 
shows only the 
ENET Configurations
 table.
3
3
To update the counters, click 
Refresh
.
The
ENET  Configurations
 view lists the Ethernet ports and their corresponding 
status.
The row headers in the first column are as follows:
Switch Port
—on card processor's connection to the switch on the SeRF card
Craft Port
—on card processor's connection to the PHY port labeled Craft
OptEnetPort1-8
—Ethernet switch interface to SFP 1-8
Network Port
—Ethernet switch interface to on-card processor
Management Port
—switch interface to the PHY port labeled Network
The column headers, from left to right, are as follows:
Rx  Bytes
—Receive byte counter. Increments by the byte count of frames 
received, including those in bad packets, excluding preamble and SFD but 
including FCS bytes
Rx  Pkts
—Receive packet counter. Increments for each frame received 
packet (including bad packets, all unicast, broadcast, and multicast 
packets)
Rx  FSC  Errors
—Receive FCS error counter. Increments for each frame 
received that has an integral 64 to 1518 length and contains a frame check 
sequence error