ADC Telecommunications Inc. PRSMAW4A 사용자 설명서
Managing Host Units
Page 218
FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc
ADCP-77-073
• Issue 2 • 11/2009
2
2
(Optional) To enlarge the view, click Full Screen to open a separate window that
shows only the
shows only the
ENET Configurations
table.
3
3
To update the counters, click
Refresh
.
The
ENET Configurations
view lists the Ethernet ports and their corresponding
status.
•
•
The row headers in the first column are as follows:
–
Switch Port
—on card processor's connection to the switch on the SeRF card
–
Craft Port
—on card processor's connection to the PHY port labeled Craft
–
OptEnetPort1-8
—Ethernet switch interface to SFP 1-8
–
Network Port
—Ethernet switch interface to on-card processor
–
Management Port
—switch interface to the PHY port labeled Network
•
•
The column headers, from left to right, are as follows:
–
Rx Bytes
—Receive byte counter. Increments by the byte count of frames
received, including those in bad packets, excluding preamble and SFD but
including FCS bytes
including FCS bytes
–
Rx Pkts
—Receive packet counter. Increments for each frame received
packet (including bad packets, all unicast, broadcast, and multicast
packets)
packets)
–
Rx FSC Errors
—Receive FCS error counter. Increments for each frame
received that has an integral 64 to 1518 length and contains a frame check
sequence error
sequence error