ADC Telecommunications Inc. PRSMAW4A 사용자 설명서

다운로드
페이지 138
SNMP Interface
Page 310
FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc
ADCP-77-073
  • Issue 2 • 11/2009
fwuRmtDARTOverTempFault
indicates a Remote DART Card Over Temperature Fault
fwuRmtDARTUnderTempFault
Indicate the Remote DART Card Under Temperature Fault
fwuRmtGPSFault
Remote GPS fault
fwuRmtLPADisableFault
Disable state of the linear power amplifier
fwuRmtLPAOverPowerFault
Internal over power fault state of linear power amplifier 
(power level is high enough to damage LPA)
fwuRmtLPAHighTempFault
Remote LPA High Temperature fault
fwuRmtLPAVswrFault
Internal VSWR fault state of linear power amplifier 
(greater than 3:1)
fwuRmtLPADcFault
Remote LPA DC fault
fwuRmtLPALoopFault
Remote LPA Loop fault
fwuRmtLPALowPowerFault
Internal low power fault state of linear power amplifier 
(the gain of one or more internal amplifiers does not 
meet specification)
fwuRmtLPADetectFault
Presence fault state of linear power amplifier (the LPA is 
missing)
fwuRmtSystemVswrFault
Remote system Vswr fault
fwuRmtNoRFPowerFault
Remote No RF Power fault
fwuRmtLNAPowerFault
Remote LNA power fault
fwuRmtFanFault
Remote system VSWR fault. This object hasn't been 
implemented in this release
fwuRmtACPowerSupplyMon4Fault
AC Power monitor 4 Fault
fwuRmtACPowerSupplyMon1Fault
AC Power monitor 1 Fault
fwuRmtACPowerSupplyMon2Fault
AC Power monitor 2 Fault
fwuRmtACPowerSupplyMon3Fault
AC Power monitor 3 Fault
fwuHstSysCardPrimaryCPFault
Primary Clock Priority Fault
fwuHstSysCardSecondaryCPFault
Secondary Clock Priority Fault
Table 12-3.  FlexWave-URH Agent MIB Traps (Cont.)
Trap Object
Description