Buffalo 09102002-0 External Photos
REPORT NO: 06J10094-10
DATE: March 2, 2006
FCC ID: FDI-09102002-0
COMPLIANCE CERTIFICATION SERVICES
Page: 10 of 39
This report shall not be reproduced except in full, without the written approval of CCS.
4.1
Simulating Liquid Parameter Check Result
Simulating Liquid Dielectric Parameter Check Result
@ Muscle 2450 MHz
Room Ambient Temperature =23
°C; Relative humidity = 35%
Measured by: Ninous Davoudi
f (MHz)
Temp. (°C) Depth (cm)
e"
Relative Permittivity (e'):
52.7
52.7762
0.14
± 5
14.9068
Conductivity (σ):
1.95
2.03175
4.19
± 5
Deviation (%)
Limit (%)
2450
21
15
Simulating Liquid
Parameters
Target
Measured
Liquid Check
Ambient temperature: 23.0 deg. C; Liquid temperature: 21.0 deg C
March 01, 2006 09:20 AM
Frequency
Ambient temperature: 23.0 deg. C; Liquid temperature: 21.0 deg C
March 01, 2006 09:20 AM
Frequency
e'
e''
2400000000.
52.9344
14.6795
2410000000.
52.9127
14.7216
2420000000.
52.8699
14.7759
2430000000.
52.8501
14.8168
2440000000.
52.8094
14.8432
2450000000.
52.7762
14.9068
2460000000.
52.7313
14.9246
2470000000.
52.6793
14.9682
2480000000.
52.6476
14.9936
2490000000.
52.6200
15.0299
2500000000.
52.5878
15.1083
The
c
onductivity (σ) can be given as:
σ = ωε
0
e''
= 2 π f ε
0
e''
where f = target f * 10
6
ε
0
= 8.854 * 10
-12