T H E   K E Y P A D   A N D   L C D   D I S P L A Y
Using the Info key
Guide to the SRX 600 receiver Rev A #10112 
Chapter 2 - - Page 22 
2
U
S I N G
 
T H E
  I
N F O
 
K E Y
The Info key provides access to the following:
• Battery voltage (main and backup) [1)Bat]
• Available memory (in Kilobytes) [2)Mem]
• Start frequency, Intermediate Filter Frequency (I.F.) and Local Oscillator 
Frequency (L.O.) [3)Freq]
• Version numbers of the Boot Code, Master and Slave [4)Ver]
• Configuration settings (Scan Time and Code Set) [5)Cfg]
• Service information (the receiver’s Serial Number and the number of hours 
that the receiver has been in operation since its last service) [6)Service]
• The factory password (123456) [7)Factory Password]
• Ability to answer an incoming call via the Modem [8)Answer Incoming Call]
The backup battery is 3.3V at full capacity. If this value should drop to 2.8V or 
less, the receiver should be returned for service. Regardless of the status of the 
battery, the receiver should be serviced every two years.
Start frequency, I.F. and L.O. are only used by Lotek Wireless Inc. for manufac-
turing purposes.
When accessing the Info key menu items it is not possible log on to the receiver; 
these features are mutually exclusive. 
A
N S W E R I N G
 
A N
 
I N C O M I N G
 
C A L L
This feature is provided for testing and troubleshooting purposes. When a 
modem is being used to access the receiver it rings when a call is made. The 
receiver is programmed to automatically answer all calls made. If the receiver 
does not answer after the modem rings 4 or more times there may be a problem 
with the auto-answer feature.
However, the call can still be answered via Info > 8)Answer Incoming Call.