Lotek Wireless Inc SRX600 사용자 설명서

다운로드
페이지 82
C O D E L O G   M O D E
1)Config## > 3)Freq/Ch
Guide to the SRX 600 receiver Rev A #10112 
Chapter 5 - - Page 56 
5
For example, if a transmitter that uses frequency 148.360 is intentionally removed 
from the reception area for a period of time, there is no point in using the receiver 
to scan that frequency. In this case the frequency can be disabled or skipped.
A frequency can be enabled or disabled via Codelog > 1)Config## > 3)Freq/CH > 
2)View/Modify > 2)En/Dis
. The display provides the only indication that the 
frequency is enabled or disabled by showing EN or DIS after the frequency 
selected.
A
S S I G N I N G
 
A
  T
R A N S M I T T E R
  T
Y P E
 
T O
 
A
  F
R E Q
/ C
H
The receiver defaults to the ID only type for new frequency+channel assignments; 
others must be specifically assigned.
Assign a transmitter type to a frequency+channel via Codelog > 1)Config## > 
3)Freq/CH > 2)View/Modify > 3)ID/Sen
. The display shows the current setting 
for the frequency (e.g. 149.891MHz CH456 EN ID), which includes the frequency, 
the channel, whether the frequency is enabled or disabled and what the 
transmitter type is.
Use the Right and Left arrow keys to go to the next frequency in the frequency 
table to change its transmitter type to sensor.
D
E L E T I N G
 
A L L
 
F R E Q U E N C I E S
 
I N
 
A
  F
R E Q U E N C Y
  T
A B L E
It is important to note that because frequencies in a frequency table are also 
copied into the master table, they can be deleted from a frequency table and still 
exist in the master table.
All frequencies in a frequency table can be deleted via Codelog > 1)Config## > 
3)Freq/CH > 2)View/Modify > 1)Del > 7)Yes or 9)No
.
E
N A B L I N G
/ D
I S A B L I N G
 
A L L
 
F R E Q U E N C I E S
 
I N
 
A
 
F
R E Q U E N C Y
  T
A B L E
All frequencies in a frequency table can be enabled (available for scanning) or 
disabled (skipped), whereby during a scan all frequencies can be temporarily