Product Engineering Specification 
 
Document 
PES-K33440 Rev
0.8
March 27, 2008
 
 
 
 
 
 Confidential 
Page 17 of 19
 
9.0
 Quality Requirements 
 
Please describe the quality requirement for this product below. The example subsections are 
given as a reference. Author may change these subsections or add more requirements according 
to the corresponding product. 
9.1 Design Workload 
This product is designed to be capable of operating 24 hours a day, 365 days a year under the 
specified environmental conditions defined in section 7.1 and 7.2. 
9.2 Reliability Requirements 
The reliability of this product shall be measured by MTBF (mean time between failures). It is the 
average time that this product is being used under its specific operating conditions before a 
failure occurs since last failure happened. It is measured in hours. 
 
The MTBF of this product is > ?????? hours. 
 
Note: The MTBF value is related to product design and manufacturing. It can be estimated based 
on the life accelerated tests. So when the product is in pre-production phase, the product life 
accelerated tests must be applied to ensure the required MTBF value is achievable.  
9.3 Acceptance Quality Level 
The MIL-STD-105E shall be used as the standard of making the random sampling inspections for 
product manufacturing. The minimum Acceptance Quality Level for this product is defined as 
following: 
 
Critical defects: no critical defect is acceptable 
Major defects: AQL  
Minor defects: AQL 
 
The author should define the AQL value based on the product characteristics. 
 
Defects Classification: 
 
Critical: likely to result in unsafe condition or contravene mandatory regulation (no critical defect is 
accepted). 
 
Major: reduces the usability of the product or is an obvious appearance defect. 
 
Minor: doesn’t reduce the usability of the product, but is a defect beyond the defined quality 
standard. 
 
The author can define these three types of defects in more detailed if it is necessary.