ACCO Brands M01042-V 사용자 설명서
Product Engineering Specification
Document
PES-K33440 Rev
0.8
March 27, 2008
Confidential
Page 17 of 19
9.0
Quality Requirements
Please describe the quality requirement for this product below. The example subsections are
given as a reference. Author may change these subsections or add more requirements according
to the corresponding product.
9.1 Design Workload
This product is designed to be capable of operating 24 hours a day, 365 days a year under the
specified environmental conditions defined in section 7.1 and 7.2.
specified environmental conditions defined in section 7.1 and 7.2.
9.2 Reliability Requirements
The reliability of this product shall be measured by MTBF (mean time between failures). It is the
average time that this product is being used under its specific operating conditions before a
failure occurs since last failure happened. It is measured in hours.
The MTBF of this product is > ?????? hours.
Note: The MTBF value is related to product design and manufacturing. It can be estimated based
on the life accelerated tests. So when the product is in pre-production phase, the product life
accelerated tests must be applied to ensure the required MTBF value is achievable.
average time that this product is being used under its specific operating conditions before a
failure occurs since last failure happened. It is measured in hours.
The MTBF of this product is > ?????? hours.
Note: The MTBF value is related to product design and manufacturing. It can be estimated based
on the life accelerated tests. So when the product is in pre-production phase, the product life
accelerated tests must be applied to ensure the required MTBF value is achievable.
9.3 Acceptance Quality Level
The MIL-STD-105E shall be used as the standard of making the random sampling inspections for
product manufacturing. The minimum Acceptance Quality Level for this product is defined as
following:
Critical defects: no critical defect is acceptable
product manufacturing. The minimum Acceptance Quality Level for this product is defined as
following:
Critical defects: no critical defect is acceptable
Major defects: AQL
Minor defects: AQL
The author should define the AQL value based on the product characteristics.
Defects Classification:
Critical: likely to result in unsafe condition or contravene mandatory regulation (no critical defect is
accepted).
Major: reduces the usability of the product or is an obvious appearance defect.
Minor: doesn’t reduce the usability of the product, but is a defect beyond the defined quality
standard.
The author can define these three types of defects in more detailed if it is necessary.