Section 1 Introduction
User Manual
Maxiva UAX Transmitter Indoor System
1.4
System Specifications
The following specifications refer to a typical 2kW outdoor enclosure system.
Specifications are subject to change and may vary depending on system configuration.
Specifications are subject to change and may vary depending on system configuration.
1.4.1
Environmental and Physical
Operating Temperature (ambient): 0
o
C. to 40
o
C
Storage Temperature (ambient): -40
o
C to 70
o
C
Humidity: 0 to 90% non-condensing.
Altitude: Maximum 4,000 meters. Derate 2 degrees C. per 300m AMSL.
Weight: Varies with model number. Consult system drawings.
1.4.2
AC power
Input voltage: 240V ±15% V, 60 Hz, single phase (transmitter)
Input voltage: 120V ±15% V, 60 Hz, single phase (MSTS equipment)
Nominal current at maximum RF output power: < 65A (transmitter)
Nominal current at maximum RF output power: < 20A (MSTS equipment)
Input Voltage Harmonics: < 5% THD
1.4.3
Connectors
Transmitter RF output: EIA 1-5/8”, 50 Ohm
ASI input: BNC, female, 75 Ohm
NOTE:
For warranty purposes, each major component in the system contains a bar code
strip. These bar codes are NOT to be removed. See example shown in Figure 1-7.