GatesAir Inc. CZF 사용자 설명서

다운로드
페이지 148
 
  
APEX
 Exciter Incorporating FLO
 Technology
Theory of Operation
DC Power Distribution
Page: 4-18
888-2604-001
03/08/07
WARNING: Disconnect primary power prior to servicing.
4.5.3.5
Up Converter Board Power
The Up Converter board receives its dc voltages (+/- 15 Vdc and +8 Vdc) from the UDC
interface board via connector J3. The up converter board supplies are listed below.
• +15 Vdc: Input power from UDC interface board via connector J1 pin 1
• -15 Vdc: Input power from UDC interface board via connector J1 pin 3
• 8 Vdc: Input power from UDC interface board via connector J1 pin 5
• An on board regulator produces +5 Vdc from the +15 Vdc supply.
+/-15 Vdc is supplied to the output amplifier from the Up Converter board via J2.
• +15 Vdc is supplied via J2 pin 1.
• -15 Vdc is supplied via J2 pin 3.
• Returns (ground) for the +/-15 volt supplied is via J2 pins 2 and 4.
The +15, -15, and +8 Vdc inputs appear on the up converter board status screen.
4.5.3.6
Output Amplifier
Power for the output amplifier is received at J5 from the up converter board via J2. The
power connections for J5 are listed below.
• +15 Vdc is received at J5 pin 1.
• -15 Vdc is received at J5 pin 3.
Returns (ground) for the +/-15 volt supplies are via J5 pins 2 and 4.