Tyco Safety Products/Sensormatic AMS1140 사용자 설명서

다운로드
페이지 15
 
AMS-1140 DETECTORS 
8200-2684-02, REV. 0 
SETUP AND SERVICE GUIDE 
15 of 15
 
Specifications 
Power Supply 
Primary Input ........................................ 100-120Vac  
or 200-240Vac @ 50-60Hz  
Primary power fuse ........................... One 2A, 250V,  
 
slo-blo, hi-breaking, 
 
5mmx20mm fuse 
Current draw .............. less than 0.5Arms @ 120Vac 
Input power ....................................... less than 44W 
Transmitter 
Operating frequency ...................... 58kHz (+200Hz) 
Transmit Burst Duration ................................. 1.6ms 
Transmit Current (in Tx coil) ..................... 42A peak 
Transmit Current (in Interconnect cable) .. 17A peak 
Burst Repetition Rate: 
Based on 50Hz ac .................................. 37.5Hz 
Based on 60Hz ac ..................................... 45Hz 
Antenna Coil Resistance ................ .25 ohms (±5%) 
Receiver 
Center Frequency .......................................... 58kHz 
Alarm 
Audio level ..................................................... 83dBA 
Environmental 
Ambient Temperature .. 0°C to 40°C (32°F to 104°F) 
Relative Humidity .............0 to 90% non-condensing 
Enclosure .......................................................... IPx0 
Mechanical 
Height .............................................. 137.1cm (54in) 
Width ................................................. 35.8cm (14in) 
Depth (base) ....................................... 8.6cm (3.4in) 
Declarations 
Regulatory Compliance  
 
EMC ............................................... 47 CFR, Part 15 
 
EN 300 330 
 
EN 301 489 
 
RSS 210 
Safety .................................................... UL 60950-1 
 
CSA C22.2.60950-1 
 
EN 60950-1 
REGULATORY PRODUCT NAME:  
ZA1140-D = TYPE: AMS-1140 
FCC ID: BVCAMS1140 
FCC COMPLIANCE: This equipment complies with Part 15 of the 
FCC rules for intentional radiators and Class A digital devices when 
installed and used in accordance with the instruction manual. 
Following these rules provides reasonable protection against harmful 
interference from equipment operated in a commercial area. This 
equipment should not be installed in a residential area as it can 
radiate radio frequency energy that could interfere with radio 
communications, a situation the user would have to fix at their own 
expense. 
EQUIPMENT MODIFICATION CAUTION: Equipment changes 
or modifications not expressly approved by Sensormatic Electronics 
Corporation, the party responsible for FCC compliance, could void 
the user's authority to operate the equipment and could create a 
hazardous condition. 
Other Declarations 
WARRANTY DISCLAIMER: Sensormatic Electronics 
Corporation makes no representation or warranty with respect to the 
contents hereof and specifically disclaims any implied warranties of 
merchantability or fitness for any particular purpose. Further, 
Sensormatic Electronics Corporation reserves the right to revise this 
publication and make changes from time to time in the content hereof 
without obligation of Sensormatic Electronics Corporation to notify 
any person of such revision or changes. 
LIMITED RIGHTS NOTICE: For units of the Department of 
Defense, all documentation and manuals were developed at private 
expense and no part of it was developed using Government Funds. 
The restrictions governing the use and disclosure of technical data 
marked with this legend are set forth in the definition of "limited 
rights" in paragraph (a) (15) of the clause of DFARS 252.227.7013. 
Unpublished - rights reserved under the Copyright Laws of the 
United States. 
TRADEMARK NOTICE: Ultra•Max and Sensormatic are 
registered trademarks of Sensormatic Electronics Corporation. Other 
product names (if any) mentioned herein may be trademarks or 
registered trademarks of other companies. 
No part of this guide may be reproduced in any form without written 
permission from Sensormatic Electronics Corporation. 
RWH 01/2010